CLEANING AND SERVICING (Cont.)
4. If the ODS pilot fl ame does not burn as indicated in the instructions, extinguish the ODS pilot by turning
the valve to the full OFF position. Using a compressed air duster (commonly available at computer,
electronic, or offi ce supply stores), insert the fl exible nozzle through either air intake openings, ensuring
that the nozzle is pointed toward the ODS pilot opening (see Fig. 25-1). Blow air through both air intake
openings to clear out any debris that may be in the system.
5. Relight the ODS pilot and inspect it to be sure it is burning as shown in the instructions. If not, extinguish
the ODS pilot and turn off the gas supply to the gas log set. Using an adjustable or a
1
/
4
" wrench,
disconnect the ODS pilot gas line from the valve (see Fig. 25-2).
6. Insert the fl exible nozzle of the compressed air duster and blow air into the input end of the ODS pilot gas
line to remove any blockages. Do not blow air directly into the ODS pilot opening. Blow air in the
direction of the gas fl ow.
7. Reinstall the ODS pilot gas line and check for leaks.
8. Light the ODS pilot to make sure it is operating properly (see the relevant LIGHTING INSTRUCTION
section).
9. If the ODS pilot still does not operate properly, it may need to be replaced with the same model as the
one on the unvented burner.
Air intake
openings
Pilot openings
Compressed
air duster
Flexible
nozzle
Air intake
openings
ODS pilot
opening
Flexible
nozzle
Compressed
air duster
ODS pilot
gas line
Air shutter
openings
ODS pilot
system
Ember burner
port holes
Burner
port
holes
Fig. 25-1