Owner`s manual

4
NO. L-F2-06609
REV 6 - 0903181423
Model
Log Set
Size
Fireplace Size
BTU Rating
(for either natural or
propane gas)
Width Depth Height
G8-16
G8-16-12(M)(P)
16
"
17" front
13" rear*
9
1
/
2
" 17"
20,000
G8-16RP 9,500
G8-20
G8-20-12(M)(P)
20
"
21" front
13
" rear*
9
1
/
2
" 17"
20,000
G8-20RP 9,500
G8-24
G8-24-12(M)(P)
24
"
26" front
13
" rear*
9
1
/
2
" 17"
20,000
G8-24RP 9,500
* These dimensions are minimums if both are measured in the same fi replace. (i.e.: 13
" rear
width is required at 9
1
/
2
" depth. Rear width can be smaller if the fi replace is deeper.)
FIREPLACE SIZE REQUIREMENTS & BTU RATING INFORMATION
The minimum size of a fi replace for installation of Real-Fyre
®
G8 vent-free gas log set: (refer to Fig. 4-1)
Fig. 4-2
Minimum Permanent Free Chimney
Vent Opening Standard Models
Table 4-2
Chimney Height
Factory built
replaces
Masonry built
replaces
15' 12.51 sq. in. 16.51 sq. in.
20' 11.24 sq. in. 15.24 sq. in.
25' 10.65 sq. in. -
30' 10.05 sq. in. 14.05 sq. in.
35' 9.46 sq. in. -
40' 8.86 sq. in. -
Minimum Permanent Free Chimney
Vent Opening RP Models
Table 4-3
Chimney Height
Factory built
replaces
Masonry built
replaces
15' 5.94 sq. in. 9.94 sq. in.
20' 5.34 sq. in. 9.34 sq. in.
25' 5.06 sq. in. -
30' 4.77 sq. in. 8.77 sq. in.
35' 4.49 sq. in. -
40' 4.20 sq. in. -
This unit may not be installed in a vented fi replace with a chimney of less than 15 feet in height.
Observing minimum fi replace dimensions and centering the appliance in the fi replace will assure
adequate clearance for operation and servicing. It may be necessary to uninstall the unit for some types
of service.