Owner`s manual
24
OPERATING THE REAL-FYRE
®
GAS LOG SET
Observe the fl ames. The fl ames should be blue at the base and a
combination of blue/yellow at the body and tips. Flames should be 2"
to 4" tall (see Fig. 24-1).
Every Real-Fyre
®
vent-free gas log set leaves the factory tested and
quality checked to ensure that it has been manufactured to the strict
specifi cations to which it was submitted and approved for certifi cation
by the American Gas Association. This check includes an operational
test to ensure both satisfactory combustion and operation.
Each installation site for any vent-free appliance presents its own
unique combustion environment. Specifi c factors such as weather
tightness of the home, size of the room in which the log set is installed,
central heating, ceiling fans, altitude, drafts, pet hair, the size of the fi replace, paint or soot inside the fi replace,
etc., all have an infl uence on the proper operation of a vent-free appliance and its ODS pilot system. A
normally operating vent-free log set will demonstrate the following characteristics:
• A lively, realistic fl ame will be blue/yellow on burner.
• Clean burning combustion, which will produce no soot or smoke, after normal break-in.
• Production of no odor, other than normal odors associated with combustion of propane or natural
gas.
• Production of water vapor. Water vapor helps to increase indoor humidity, which may be benefi cial
during the dry heating season.
If you operate the vent-free gas log set fueled by propane gas, operating characteristics may vary as the
fuel in the tank approaches empty (less than
1
/
4
full). Sooting and other increases in combustion by-products
will occur. Turn off the log set and re-fi ll the propane tank.
CHECKING THE ODS PILOT FLAME APPEARANCE
When installing the G8 burner assembly, it is important to visually check the ODS pilot fl ame and burner
fl ames.
1. The ODS pilot fl ame must be present when the burner is operating. The fl ame should touch the top of the
thermocouple tip.
2. If the ODS pilot fl ame does not touch the top of the thermocouple tip, then the main burner will not function
properly (see Fig.
24-2 - for incorrect ODS pilot fl ame).
3. With the burners off and the ODS pilot fl ame off, and the assembly cool, check the burner assembly, air
intake openings on the ODS and air shutter openings on the burner for any blockages that could affect
the operation of the ODS pilot fl ame.
ODS PILOT FOR G8
(NG shown)
Correct ODS pilot fl ame
Incorrect ODS pilot fl ame
Fig. 24-2 Fig. 24-3
WARNING: NO ADJUSTMENTS ARE TO BE MADE TO THE ODS PILOT SYSTEM. TAMPERING WITH
THIS SYSTEM CAN BE EXTREMELY HAZARDOUS.
Fig. 24-1