LIGHTING INSTRUCTIONS FOR REMOTE READY 12 SERIES VALVE
FOR YOUR SAFETY, READ BEFORE LIGHTING
1. STOP! Read the safety information (refer to the TABLE
OF CONTENTS).
2. Tu r n
OFF any electrical appliance (such as the Peterson
Warm Air Circulator) if used with the log set.
3. Check toggle switch (located on right side of front plate,
next to Piezo button) is set in the OFF position (down).
Check the safety valve knob is in the OFF position (see
Fig. 23-1). Do not force.
4. Wait fi ve (5) minutes to clear out any gas. If you then
smell gas, STOP! FOLLOW ‘B’ in the safety information
on page 22. If you don’t smell gas, go to the next step.
5. Turn the safety valve knob (one quarter turn)
counterclockwise to the PILOT position (see Fig.
23-2). Push the safety valve knob fully and hold. At
the same press the piezo ignitor button (located on right
side of front plate) several times. The ODS pilot will light.
The ODS pilot is located left of center below main burner
pipe (see PARTS LIST). Hold the safety valve knob
in for approximately 60 seconds (Fig. 23-3).
CAUTION: IF THE GAS SET DOES NOT IGNITE
WITHIN 20 SECONDS, STOP, TURN
THE SWITCH TO OFF, WAIT 5 MINUTES
THEN REPEAT STEPS 3-6.
Normally, the ODS pilot should remain lit. If it goes
out, repeat step 3 through 6.
If the ODS pilot does not stay lit, turn the safety valve
knob to the full OFF position. Wait fi ve minutes and
repeat the lighting instructions.
6. With the ODS pilot lit, allow the safety valve
knob to pop up, then turn it (one quarter turn)
counterclockwise to the ON position.
Flip the toggle switch (located at the right side of front
plate) UP to the
ON position and the gas log set will
light.
7. Periodically check the ODS pilot fl ame for proper fl ame
pattern. Reference the section CHECKING THE ODS
PILOT FLAME APPEARANCE.
TO TURN OFF GAS TO THE APPLIANCE
To turn off the gas log set, ip the toggle switch DOWN to
OFF (Down) position. The ODS pilot will remain lit.
To turn off the ODS pilot, be sure the toggle switch is
OFF
slightly depress and turn the safety valve knob (one half turn)
clockwise
to the OFF position.
FOR REMOTE LIGHTING
For units equipped with a remote transmitter and
receiver, follow the separate instructions that come with
the remote to light the burner remotely.
ON
OFF
PILOT
ON
OFF
PILOT
ON
OFF
PILOT
Fig. 23-1
Fig. 23-2
Fig. 23-3
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
Safety valve
control knob
Toggle
switch
Piezo
ignitor
Fig. 23-4
Control knob
in OFF position
Read setting
here
Note: Toggle switch is set
to OFF (down)
Control knob
in PILOT position
Read setting
here
Note: Toggle switch is set
to OFF (down)
Piezo button
Control knob
in ON position
Read setting
here
Note: Toggle switch is set
to OFF (down)