Owner`s manual

21
CLEANING AND SERVICING (Cont.)
Air intake
openings
ODS pilot opening
Compressed
air duster
Flexible
nozzle
4. If the ODS pilot fl ame does not burn as indicated in the instructions, extinguish the ODS pilot by turning
the valve to the full OFF position. Using a compressed air duster (commonly available at computer,
electronic or offi ce supply stores), insert the fl exible nozzle through either air intake openings, insuring
that the nozzle is pointed toward the ODS pilot opening (see Fig. 21-1). Blow air through both air intake
openings to clear out any debris that may be in the system.
5. Re-light the ODS pilot and inspect it to be sure it is burning as shown in the instructions. If not, extinguish
the ODS pilot and turn off the gas supply to the gas log set. Using an adjustable or a
1
/
4
" wrench,
disconnect the ODS pilot gas line from the valve.
6. Insert the fl exible nozzle of the compressed air duster and blow air into the input end of the ODS pilot gas
line to remove any blockages (see Fig.
21-1). Do not blow air directly into the ODS pilot opening.
Blow air in the direction of the gas fl ow.
7. Re-install the ODS pilot gas line and check for leaks.
8. Light the ODS pilot to make sure it is operating properly (see the relevant LIGHTING INSTRUCTIONS
section).
9. If the ODS pilot still does not operate properly, it may need to be replaced with the same model as the
one on the vent-free burner.
Fig. 21-1
Fig. 21-2
ODS pilot location
Burner ports
Air shutter