Owner`s manual

16
Note: We recommend that before you install the log set, you familiarize yourself with the control
valve layout. This will help you to be confi dent operating the log set when fully installed
(see the fi gures below for typical control positions).
MANUAL
VALVE SETTINGS
1. Center the burner assembly in the fi replace. Make certain
that no part of the assembly protrudes beyond the face
of the fi replace.
2. Attach the large adaptor fi tting of the fl ex connector kit
(Item 8, Item 28) to the gas supply line using a pipe
compound resistant to propane gas or Tefl on tape. Tighten
the connection. Connect one end of fl ex connector to the
large adaptor, and the other end to the fl are connector
fitting on the burner assembly (see Fig.
16-1). For
remote ready valves connect the fl ex connector to the
brass connector on the safety valve (see Fig. 16-2).
3. Make sure that the control valve on the assembly is in the
OFF position (see Fig.
16-3 & Fig. 16-4). Carefully turn on
the gas to the fi replace and leak test at all connections
by applying a soapy water solution to their surface. If
bubbles appear, a leak is present. Turn off gas and tighten
all connections, then turn on the gas and repeat the leak
test. Never use an open fl ame to check for leaks.
CONNECTING THE GAS TO THE BURNER SYSTEM (Cont.)
Two security holes are provided in the base plate
assembly for securing it to the fi replace fl oor in a
mobile home, or if the installation or inspector require
it in other circumstances. To attach the burner, center
it properly in the fi re place and secure with appropriate
screws (not provided). See Fig. 16-5. You may
have to drill holes in the fl oor of the fi replace (Note:
If you have a manufactured fi replace, check with the
manufacturer before drilling holes in the fl oor). Indicate
hole placement with the security holes in the base
plate assembly, then drill and attach with screws.
Fig. 16-5
Fig. 16-1
Safety
valve
Fasten flex
connector
here
ATTACHING THE BURNER PLATE TO THE FIREPLACE FLOOR
Fig. 16-3
ON PILOT OFF
ON
OFF
PILOT
ON
OFF
PILOT
ON
OFF
PILOT
REMOTE READY 12 SERIES
VALVE SETTINGS
Fig. 16-4
Fig. 16-2
Important: For all valves, the air MUST be purged from the gas line before the ODS pilot will light
properly. The time taken to do this will depend on the length of gas line from the meter to
the unit and the length of time since the unit or gas line was last used (in the case of non-
use during warm weather for example). It may take from 3-15 minutes before all the air
is purged and the ODS pilot will light properly. This is done using the method for lighting
the ODS pilot, but holding in the control valve for a longer period. Follow the LIGHTING
INSTRUCTIONS in this manual for the specifi c valve type.
ON PILOT OFF