Owner`s manual
4
SPECIFICATIONS
Real-Fyre gas burner systems must be installed only in a wood burning fi replace with the minimum fi rebox
dimensions and venting requirements met (see table on this page). This appliance is designed to burn with
yellow fl ames; adequate ventilation is absolutely necessary.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fi replaces
Chimney height 18/20" 24/30"
15' 20 24
20' 17 21
30' 14 16
For masonry-built fi replaces
15' 30 35
20' 27 32
30' 25 29
Note: The minimum chimney height from hearth to top of chimney is 15'.
Table 2 - Minimum Chimney Damper Vent Opening Requirements
Burner
Model
Minimum Fireplace Size BTU Rating
Width
Depth Height Nat. Gas
Front Rear
G52-18/20 27" 19" 16" 15" 46k
G52-24/30 (24" log set) 33" 25" 16" 15" 55k
G52-24/30 (30" log set) 39" 32" 16" 15" 55k
Table 1 - Minimum Fireplace Dimensions and BTU ratings
Note: Rear width is at corresponding depth.