Owner`s manual

33
LIGHTING INSTRUCTIONS - 2VA SERIES (cont.)
Fig. 33-3 Proper pilot fl ame
MANUAL LIGHTING
CAUTION: DO NOT attempt to light the pilot by hand.
1. Locate the OFF/REMOTE switch actuator on the left
rear of the burner. Slide the actuator to the left / OFF
position. See Fig. 33-1.
2. Locate the ON/OFF switch at the front of the switch box.
Press the switch to the ON (I) position. See Fig. 33-2.
The remote receiver will emit an audible "beep"; then
the igniter will begin to spark. After the pilot lights and
is established, the valve will automatically open and
the burner will light.
Note: The ignition sequence will take approximately 5
seconds.
WARNING: If the pilot fails to light within 10 seconds,
turn OFF the system. Allow fi ve (5) minutes
for any gas in the unit to dissipate, then
repeat step 2 above. IF YOU SMELL GAS,
SEE STEP B ABOVE.
If the pilot fails to light after several tries, turn the system
OFF and contact a qualifi ed professional service technician.
Note: In manual mode, the remote transmitter will not
operate the burner system.
SHUTTING DOWN
For remote shut down, press the OFF button on the
remote transmitter.
If remote is unavailable, slide the OFF/REMOTE
switch actuator (on left rear of burner) to the left /
OFF position.
• For manual shutdown, press the ON/OFF switch
on the front of the switch box to the OFF (O) position.
PILOT APPEARANCE
Periodically check the pilot for proper fl ame pattern. The
pilot fl ame should encircle the electrode tip, and is preset
at the factory (see Fig. 33-3).
If the pilot fl ame burns incorrectly; shut down completely
and contact a qualifi ed professional service technician.
I
O
Fig. 33-1
OFF/REMOTE switch actuator (left rear of burner)
ON
Fig. 33-2
Switch box,
ON/OFF
switch detail
OFF
Remote receiver