DAMPER CLAMP INSTRUCTIONS
The damper clamp with hex bolt (Figure 1) is provided as a means to prevent full closure of the
damper blade. The clamp is easily attached to most damper blades with pliers or wrench, and must
be permanently installed. The clamp is designed to prevent accidental closure of the damper when
installed as illustrated (Figures 2 A&B). Should the clamp not fi t, or provide the permanent vent opening
listed on the table found on page 7, have a permanent stop installed, remove the damper blade or
have the damper cut to provide the minimum permanent opening required.
DAMPER STOP CLAMP INSTRUCTIONS
Your Peterson Real-Fyre gas log set must be installed by an NFI Certifi ed or other qualifi ed, professional
installer. Instructions must be followed carefully to ensure proper performance and an aesthetically
pleasing product. Check to be sure your log set is designed and labeled for the type of gas (natural
or propane gas) supplied to your fi replace. Never use a log set designed for natural gas with propane
gas or a log set designed for propane gas with natural gas. Real-Fyre gas logs must be installed only
in a wood-burning fi replace with the minimum venting requirements met (see page 7). Fireplace fl oor
must be level, clean and smooth. Check parts list to be sure all parts are included. Gas supply pipe
inside diameter (I.D.) must be 1/2" or larger. 3/4" I.D. may be necessary if gas line is longer than 20'.
You should adjust and align the pilot prior to installing by using the fl ex connector kit (Item 16). Attach
your connector kit to the gas supply and the burner outside the fi replace. This will allow you to move
the burner at an angle in order to access the pilot adjustment screw on the valve (see page 24 for pilot
adjustment).
INSTALLING YOUR REAL-FYRE GAS LOG SET
CONNECTOR KIT
GAS
SUPPLY
LARGE ADAPTER
BURNER
VALVE
GAS INLET
ELBOW
Postion of Burner Gas Inlet Valve on
G46-11 Model
Figure 3
Figure 2A Figure 2B
Damper Clamp
Figure 1
SET SCREW
Open Closed