Owner`s manual
20
FOR YOUR SAFETY, READ BEFORE LIGHTING
The Real-Fyre G46 Series gas log set has a pilot which can be lit by hand using the piezo ignitor. When lighting
the pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the gas log set area for gas. Be sure to smell next to the fl oor as some gas
is heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON PAGE 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by
hand, don't try to repair it. Call a qualifi ed, professional service technician. Force or attempted repair may result in
fi re or explosion.
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will help
you to be confi dent operating the log set when fully installed (see Figures on page 16-23 for typical control positions).
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
TO LIGHT THE PILOT AND MAIN BURNER.
1. STOP! Read the safety information above.
2. Turn "OFF" any electrical appliance (such as the Peterson warm air circulator system) if used with the log
set.
3. Place the "switch" (marked " I" = "IGNITE"; "O" = "OFF" , Figure 22) in "OFF" position.
4. Wait fi ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the instructions on Page 1.
5. Press the switch on top of the pine cone to the "I" position (see Figure 23). A rapid series of sparks at the pilot
(cobra) head. These sparks cease when the pilot fl ame is lit and stable. When the pilot becomes stable the
electronic valve will open and light the main burner.
CAUTION: IF THE GAS SET DOES NOT IGNITE WITHIN 20 SECONDS, STOP, WAIT 5 MINUTES THEN
REPEAT "TO LIGHT THE PILOT AND MAIN BURNER".
LIGHTING INSTRUCTIONS FOR G46-01 GAS LOG SET
THIS UNIT (G46-01) HAS A NON-STANDING PILOT.
1. Press the switch on top of the pine cone to the "O" position ("O" = "OFF", Figure 24). The gas fl ow will cease
and all fl ames (main burner and pilot) will go out.
PINE CONE SWITCH
Figure 22
Figure 23
Figure 24
PINE CONE SWITCH
IN "ON" POSITION
PINE CONE SWITCH
IN "OFF" POSITION
TO TURN OFF THE G46-01 REMOTE GAS LOG SET