Owner`s manual
18
1. STOP! Read the safety information above.
2. Turn "OFF" any electrical appliance (such as the Peterson warm air circulator or remote control system)
if used with the log set.
3. Place the "switch" or "remote" in "OFF" position.
4. Push in the control knob and turn clockwise
to the "OFF" position.
5. Wait fi ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the instructions on Page 1.
6. Find the pilot by following the metal tube from the gas control. Pilot is located at the right rear of the burner
pan.
7. Turn the gas control knob counterclockwise
to "PILOT" (Figure 21). Push the control knob all the way
in and hold it. Press the igniter button several times to light the pilot. Continue to hold the control knob
for approximately one minute after the pilot is lit. When you release the knob, it will pop out and the pilot
should remain lit.
• If the knob does not pop out when released, STOP! Immediately call your service technician or gas sup-
plier.
• If the pilot will not light, repeat steps 4 - 7 and light the pilot manually.
• If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service
technician or gas supplier.
8. Turn gas control knob counterclockwise
to "ON".
9. If an electrical appliance is used with the log set, turn on or reconnect that appliance.
10. To operate, fl ip the "toggle switch" to "ON" or put the remote handset in the "ON" position.The burner will
ignite.
NOTE: Periodically check the pilot fl ame for proper fl ame pattern (see Figure 28).
MAKE SURE THE THERMOPILE AND PILOT ASSEMBLY ARE IN CORRECT ALIGNMENT WITH EACH
OTHER (SEE FIGURE 28, PAGE 24).
FOR YOUR SAFETY, READ BEFORE LIGHTING
The Real-Fyre G46 Series gas log set has a pilot which can be lit by hand using the piezo ignitor. When lighting
the pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the gas log set area for gas. Be sure to smell next to the fl oor as some
gas is heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON
PAGE 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it. Call a qualifi ed, professional service technician. Force or attempted repair may
result in fi re or explosion.
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will help
you to be confi dent operating the log set when fully installed (see Figures on pages 16-23 for typical control positions).
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS FOR G46-11 REMOTE GAS LOG SET
1. Place the remote or switch in the "OFF" position. The pilot will remain lit.
2. If complete shutdown is desired, remove the radiant heat shield. Push in the control knob and turn clock-
wise
to the "OFF" position. Replace the radiant heat shield.
1. LIGHTING - turn
knob to "OFF"
and wait 5 minutes
before lighting.
TOGGLE
SWITCH
CONTROL
KNOB
PILOT ADJUSTMENT
UNDER CONTROL
KNOB
HEAT SHIELD
OFF PILOT ON
2. Turn dial to ''PILOT"
position. With
match ready press
knob in and hold for 60
seconds while lighting
pilot.
3. Turn knob to "ON"
to light burner.
1. Use "OFF"
only when complete
shutdown is neces-
sary.
ON
OFF
PILOT
ON
OFF
PILOT
ON
OFF
PILOT
ON
OFF
PILOT
Figure 21
TO TURN OFF THE G46-11 REMOTE GAS LOG SET