Owner`s manual
16
1. Use "OFF" only
when complete shutdown
is necessary.
1. STOP Read the safety information on this page.
2. Turn "OFF" any electrical appliance (such as the Peterson warm air circulator) if used with the log set.
3. Push in the gas control handle slightly and turn clockwise
to "OFF" (Figure 20).
NOTE: The handle cannot be turned from "PILOT" to "OFF" unless the handle is pushed in slightly. Do not
force.
Wait fi ve minutes to clear out any gas. If you then smell gas, STOP! Notify your gas supplier or the fi re department
immediately. If you don’t smell gas, go on to step 4.
4. Turn the gas control handle counterclockwise
to "PILOT" (Figure 20). Push the control handle all the way
in and hold it. Press the igniter button one or more times to light the pilot. Continue to hold the control handle
for approximately one minute after the pilot is lit. When you release the handle, it will pop out and the pilot
should remain lit.
• If the handle does not pop out when released, stop and immediately call your service technician or gas
supplier.
• If the pilot will not light, repeat steps 3 - 4 and light the pilot manually.
• If the pilot will not stay lit after several tries, turn the gas control handle to "OFF" and call your service technician
or gas supplier.
5. If an electrical appliance is used with the log set, turn on or reconnect that appliance.
6. Turn the gas control handle counterclockwise
to "ON" (Figure 20) to ignite the burner.
NOTE: Periodically check the pilot fl ame (Figure 26, page 24) for proper fl ame pattern.
MAKE SURE THE THERMOCOUPLE AND PILOT ASSEMBLY ARE IN CORRECT ALIGNMENT WITH EACH
OTHER. (SEE FIGURE 26, PAGE 24).
LIGHTING INSTRUCTIONS FOR G46 MANUAL GAS LOG SETS
TO TURN OFF THE MANUAL GAS LOG SET
1. From the "ON" position, turn the control knob clockwise to the "PILOT" position. The log set will extinguish
and the pilot will remain lit.
2. If complete shutdown is desired, from the "PILOT" position, push in the control knob slightly and turn clockwise
to the "OFF" position. Do not force the knob.
FOR YOUR SAFETY, READ BEFORE LIGHTING
The Real-Fyre G46 Series gas log set has a pilot which can be lit by hand using the piezo ignitor. When lighting
the pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the gas log set area for gas. Be sure to smell next to the fl oor as some gas is
heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON PAGE 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by
hand, don't try to repair it. Call a qualifi ed, professional service technician. Force or attempted repair may result
in fi re or explosion.
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will help
you to be confi dent operating the log set when fully installed (see Figures on page 16-23 for typical control positions).
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
Figure 20
1. LIGHTING - turn knob to "OFF"
and wait 5 minutes before lighting.
2. Turn Dial to "PILOT"
position. With match
ready press knob in and
hold for 60 seconds while
lighting pilot.
3. Turn knob to "ON"
to light burner.
PILO T
ON
OFF
OFF
ON
PILOT
OFF
ON
PILOT
OFF
ON
PILOT