SECURING THE BURNER
Your gas log set has 2 securing holes at the front of the burner pan heat shield (see parts list and Figure
8 for location). Mark the center point of each hole and drill a 3/16" pilot hole (one for each side) into the
fi replace fl oor. Secure with 1/4" anchor bolts.
GRANULE PLACEMENT
Fill the burner pan completely with granules (Item 13). Slope the granules at the same angle as burner pan.
Do not allow granules to spill over front lip, sides or back of the burner.
DO NOT PLACE GRANULES ON
IGNITOR SHIELD OR KNOB SHIELD.
EMBER PLACEMENT
After breaking up any clumps, sprinkle embers (Item 14), lightly and evenly over entire surface of the granules.
You may sprinkle the embers (not the granules) over knob and ignitor shields, making sure to keep embers
clear of pilot assembly.
Embers around the pilot will block air fl ow, causing the pilot to overheat and shutdown the system.
To check operation, light pilot and burner (pages 16-23).
IMPORTANT
For all valves, the air MUST be purged from the gas line before the pilot will light and burn properly. The time needed
to purge will depend on the length of the gas line to the unit and the amount of time since the unit or gas line was
last used. It may take several minutes before all the air is purged and the pilot will light and burn properly. Follow the
"Lighting Instructions" (pages 16-23) in this manual.