CONNECTING THE IGNITION PACK TO THE G46-01(P) VALVE
The G46-01-xx(P) valve comes complete with the wiring harness connected to the pine cone switch. You may
wish to ensure it is correctly connected before fi nally connecting the 3 wires to the valve as below.
PINE CONE PLACEMENT
The designer pine cone incorporating
the control switch is aesthetically
designed and is an integral part of the
operation of your set. The pine cone
can be placed as close to the valve
as you desire, but never closer than
4" from the fl ame.
CAUTION: THE PINE CONE MAY
BE HOT DURING AND DIRECTLY
AFTER OPERATION OF YOUR
GAS LOG SET.
G46
Electronic
Valve
TO PILOT ASSEMBLY
PROBES
I
S
VALVE MAGNET
WIRE (BLACK)
(DO NOT REMOVE)
IGNITOR PACK
PINE CONE
SWITCH
WIRE HARNESS
(BLACK) TO
BATTERY
HOLDER
(BROWN)
2 WIRES
TO SWITCH
GREEN (TH)
BLACK (TP)
ORANGE (THTP)
I
S
(RED) TO
BATTERY
HOLDER
(Drawings not to scale.)
Wiring Diagram for 01 remote switch
INSTALLING YOUR REAL-FYRE GAS LOG SET (Continued)
SPECIAL INSTRUCTIONS FOR G46-01-xx(P) MODELS
Installing pine cone with switch for 01M models
TO CHECK THE WIRING ASSEMBLY:
A. Check that the wiring harness is fi tted tightly into the
connector on the green ignitor pack in the rear of the
pine cone (Figure 5A).
B. Check that the female connectors on the two black wires
from the pilot assembly (wires marked "I" and "S") are
inserted fully into the male connectors on the ignitor pack
(Figure 5B).
C. Check the connection of the red and black wires of the
wire harness to the respective counterpart wires from the
battery holder (red-red and black-black). The two brown
wires should be connected to the switch.
Note: the 2 spare brown wires with coated male connectors
are used to connect an optional remote system.
D. Finally connect the wires to the valve in the following
order (see Figure 6):
Orange wire marked THTP - to THTP connector on valve
Black wire marked TP - to TP connector on valve
Green wire marked TH - to TH connector on valve
CHECK CONNECTIONS
I WIRE
S WIRE
WIRE HARNESS
CONNECTOR
IGNITOR PACK
B
A
Figure 5
STEP 5 (A-B)
INSTALLING OR REPLACING BATTERIES FOR IGNITION
MODULE PACK
Two 1.5-volt (D-cell) alkaline batteries are supplied with your
log set. To install or replace batteries, remove the green ignition
module pack, held in place with a velcro strip, from rear of the pine
cone receiver (Figure 7). Remove battery holder and old batteries
from the pine cone. Replace (or install) batteries into the battery
holder, making sure they are installed according to the diagram in
battery holder. Replace holder, pressing it fi rmly against the velcro
strip. Replace ignition pack and press fi rmly into place. The ignition
system is now ready to operate.
NOTE: For your system to work properly, it is suggested that you
replace batteries annually with fresh batteries. Always replace all
the batteries at the same time.
Battery holder
with batteries
Pine cone
cover
with switch
Ignition Module Pack
Velcro
strips
GREEN
WIRE
MARKED
TH
BLACK
WIRE
MARKED
TP
ORANGE
WIRE
MARKED
THTP
D
Figure 6
STEP 5(D)
Figure 7