Owner`s manual

LIGHTING INSTRUCTIONS - MANUAL PILOT VALVE
The Real-Fyre
®
burner system has a pilot that can be lit by hand using a match or lighter. When lighting the pilot, follow these
instructions exactly.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the fl oor, as some gas is heavier than
air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't
try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.
WARNING
If you do not follow these instructions exactly, a fi re or explosion may result, causing property
damage, personal injury, or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to
inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
FOR YOUR SAFETY, READ BEFORE LIGHTING
LIGHTING THE PILOT
1. If the burner control valve knob is not in the OFF
position, push in the gas control handle slightly
and turn clockwise
to OFF (Fig. 21-1).
Refer to the PARTS LIST for the location of the
burner control valve knob.
Note: The burner control knob cannot be turned
from PILOT to OFF unless the handle is
pushed in slightly. Do not force.
Wait fi ve minutes to clear out any gas. If you then
smell gas, STOP! Notify your gas supplier or the
re department immediately. If you don’t smell gas,
go on to step 2.
2. Turn the burner control knob counter-clockwise
to PILOT (Fig. 21-1). Push the control
handle all the way in and hold it. Hold a long
replace match or lighter near the thermocouple
to light the pilot. Continue to hold the control
knob for approximately 30 seconds after the
pilot is lit to allow the thermocouple to detect
the pilot fl ame, then release the knob. The pilot
will remain lit.
If the pilot will not light, repeat steps 1 and 2.
If the pilot will not stay lit after several tries, turn
the gas control handle to OFF and call your
service technician or gas supplier.
IGNITING THE MAIN BURNER
1. Make sure the pilot is burning.
2. Turn the gas control handle counterclockwise
to ON (Fig. 21-1) to ignite the burner. The
burner will ignite.
Note: Periodically check the pilot fl ame for the
proper fl ame pattern (
Fig. 21-1).
MAKE SURE THE THERMOCOUPLE AND PILOT
ASSEMBLY ARE IN CORRECT ALIGNMENT WITH
EACH OTHER (
Fig. 21-1).
TURNING OFF THE MAIN BURNER
1. From the ON position, turn the control knob
clockwise
to the PILOT position. The burner
will extinguish, and the pilot will remain lit.
EXTINGUISHING THE PILOT
1. If complete shutdown is desired, from the PILOT
position, push in the control knob slightly and
turn clockwise
to the OFF position. Do not
force the knob. This will require the pilot to be
relit before using the burner again.
21
1. Turn the knob
clockwise to
OFF
only
when complete
shutdown is
desired.
Fig. 21-1
1. Lighting -Turn the burner control knob
to OFF
and wait 5 minutes before
lighting.
2. Turn knob
counterclockwise
to PILOT position. With
match ready, press
knob in and hold for 60
seconds while lighting
pilot.
3. Turn the knob
counterclockwise
to ON to light the
burner.
PILO T
ON
OFF
OFF
ON
PILOT
OFF
ON
PILOT
OFF
ON
PILOT
Thermocouple
The Real-Fyre
®
burner system has a pilot that can be lit using the built-in piezo ignitor switch on the burner, or by hand using
a match or long-necked lighter. When lighting the pilot, follow these instructions exactly.
2. Turn the burner control knob counterclockwise
to PILOT (Fig. 21-1). Push the control
handle all the way in and hold it. Push in the
piezo ignitor button several times until the pilot
lights. Continue to hold the control knob for
approximately 60 seconds after the pilot is lit
to allow the thermocouple to detect the pilot
ame, then release the knob. The pilot will
remain lit.