Owner`s manual
13
REV 4 - 0705040838
No.L-A2-21507
1. The burner gas inlet is located in front of the
gas valve (Fig. 10-4). Use Tefl on tape or pipe
compound on all pipe thread male connections,
except where brass to brass.
FOR THE G46 AUTOMATIC MILLIVOLT VALVE
Attach the connector kit
3
/
8
" adapter to the brass elbow
(Item 24) on the valve. The log set user should make
themselves familiar with the valve control layout before
installing the burner into the fi replace.
2. Next, clamp the log locators onto the grate fi ngers
(on the second fi nger in from each side). The log
locators will fi t on either side of the grate fi nger (see
Fig. 13-1 & 13-2). Align the locator screw so
that it projects down into the locator holes on the
burner. Attach nuts to screws and fi nger-tighten
only. Place the bottom log on the grate (see Fig.
13-3) and align the log against the locator. Fully
tighten the screws and then remove the logs and
grate until completing the gas connection and
granule placement.
3. Position the burner in the center rear of the fi replace.
Connect the connector kit tubing (Item 16) to the
gas supply. Be sure that the burner assembly and
the valve remain in alignment. If the valve shifts
position during installation, the burner assembly
may not sit fl at in the fi replace, causing improper
gas fl ow. It may also cause interference with the
control knob operation.
• Make sure that the safety control system is in the
OFF position.
• Turn on the gas to the fi replace and check for
leaks at all connections by using a soapy water
solution.
Never use an open fl ame to check for leaks.
• Light the pilot (see the relevant LIGHTING
INSTRUCTIONS section) and check for proper
adjustment. If the pilot needs to be adjusted, follow
the relevant PILOT BURNER ADJUSTMENT
section. Turn the pilot off.
• Position the grate on the burner (
Fig. 13-3). Push
the burner grate assembly as far as possible to
the rear of the fi replace, then remove the grate.
Note: Refer to the PARTS LIST when following these instructions.
CAUTION: Turn off the gas to the fi replace before beginning this procedure.
Important: Log locators may be installed in either
confi guration (A or B), depending on
burner size. Adjust as necessary to
ensure screws fi t in locator holes in
burner. This secures the burner and
grate from movement, and keeps
the logs in place for optimum log set
operation.
INSTALLING THE GAS LOG SET (Cont.)
Note: If the log set is a G46-01(M)(P) model, continue following the
instructions on p. 12. For all other models, proceed to p. 13.
Fig. 13-3
Log
locator
screw
Heat chamber
Burner
Grate
Log
locators
Front
bottom
log
Rear
bottom
log
B
A
Note: Manual grate shown.
Fig. 13-1
Fig. 13-2
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.