Owner`s manual
12
REV 4 - 0705040838
No.L-A2-21507
DAMPER CLAMP INSTRUCTIONS
The damper clamp with hex bolt (Fig. 12-1) is provided as a means to prevent full closure of the damper blade.
The clamp is easily attached to most damper blades with pliers or a wrench, and must be permanently installed.
The clamp is designed to prevent accidental closure of the damper when installed as illustrated (
Fig. 12-2 &
Fig. 12-3
). Should the clamp not fi t or provide the permanent vent opening listed on the table found on the
previous page, have a permanent stop installed, remove the damper blade, or have the damper cut to provide
the minimum permanent opening required.
DAMPER STOP CLAMP INSTRUCTIONS
The Peterson Real-Fyre
®
gas log set must be installed by an NFI Certifi ed or other qualifi ed professional installer.
Instructions must be followed carefully to ensure proper performance and an aesthetically pleasing product. Check
to be sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to
the fi replace. Never use a log set designed for natural gas with propane gas, or a log set designed for propane
gas with natural gas. Real-Fyre
®
gas logs must be installed only in a wood-burning fi replace with the minimum
venting requirements met (see the previous page). Fireplace fl oor must be level, clean, and smooth. Check
PARTS LIST to be sure all parts are included. Gas-supply pipe inside diameter (I.D.) must be
1
/
2
" or larger.
3
/
4
"
I.D. may be necessary if gas line is longer than 20'.
You should adjust and align the pilot prior to installing by using the fl ex connector kit (Item 16). Attach the connector
kit to the gas supply and the burner outside the fi replace. This will allow you to move the burner at an angle in order
to access the pilot adjustment screw on the valve (see the relevant PILOT BURNER ADJUSTMENT section).
WARNING:
This appliance is equipped for either natural or propane gas as indicated on the back cover. Field conversion is
not permitted.
INSTALLING THE GAS LOG SET
Damper clamp
Fig. 12-1
Set screw
Fig. 12-2 Fig. 12-3
Open
Closed
Position of burner gas inlet valve on
G46-11 model
Fig. 12-4
Large adapter
Gas supply
Elbow
Connector kit
Burner valve
gas inlet