Owner`s manual

14
Position the burner pan in the center of the fi replace.
Do not push up against the rear fi replace wall.
7. Connect the unconnected end of the fl ex connector to the control valve input or regulator if
connected externally to the valve. (Fig. 14-1, 2, 3, 4). DO NOT kink tubing. Tighten both
ends of the fl ex connector securely.
8. Leak testing
Carefully turn on the gas supply and leak test at all connections with a soapy water solution (equal
parts liquid detergent and water) at all connections. If bubbles appear, a leak is present. Turn off gas
and tighten connection; turn on gas and repeat leak test. Repeat until no leaks are detected. Never
use a fl ame to test for leaks.
When there are no leaks, turn off the gas supply and proceed.
INSTALLATION (Continued)
Fig. 14-1 Fig. 14-2
Fig. 14-3
Fig. 14-4
Series 11
valve
Series 01
valve
Series 15
valve
Series 16
valve
WARNING: Failure to position the parts in accordance with these instructions and diagrams, or
failure to use only parts specifi cally approved with this appliance, can result in property
damage or personal injury.