Owner`s manual

5
L-A2-20707REV 5 - 0705071310
2. Locate the gas-supply line valve and make sure it is in
the OFF position.
INSTALLATION
Fig. 5-1 Damper clamp in place
1. A damper clamp (Item #7) is supplied and must be installed
on the damper assembly as shown (Fig. 5-1).
a. Open the fi replace damper.
b. Attach the damper clamp on the damper blade and
secure with the bolt.
Note: The damper clamp must be permanently installed.
Should the clamp not fi t, install a permanent damper
stop or other means of preventing full or accidental
closure.
When your gas log set is operating, the damper must be
fully open.
Open Closed
TO INSTALL THE GAS LOG SET, THE
FOLLOWING STEPS MUST BE FOLLOWED.
3. Locate the gas-supply stub inside the fi replace.
a. Remove the cap, if attached (see Fig. 5-2).
OFF
Use second
wrench to
stop pipe
from turning
Use wrench to
remove stub cap
Fig. 5-2 Removing the stub cap
Fig. 5-3 Attaching the elbow
Fig. 5-4 Adapter on pan
This gas log set must be installed by an NFI Certifi ed or other qualifi ed installer. The installation,
including provisions for combustion and ventilation air, must conform with local codes, or in the absence of
local codes, with the latest edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54).
Caution: When removing the cap, make sure the stub
does not turn, loosening the connection inside
the wall.
5. Attach the small elbow (Item #8C) to the fuel injector
or air mixer on the burner pan (see Fig. 5-4), using
Te on tape or pipe compound. Tighten securely.
4. Attach the large elbow (Item #8A) to fi replace gas stub
(see Fig. 5-3), using Tefl on tape or pipe compound
on the stub. Tighten securely.
DO NOT REMOVE THE
FUEL INJECTOR/AIR MIXER
Fuel injector
or air mixer
Attach large elbow
to stub
Attach small adapter to fuel
injector on burner pan