Owner`s manual
8
INSTALLATION (cont.)
6. Be sure gas to the fi replace is off. Remove the adapter
that is loosely connected to the open end of the fl ex
connector. Attach the adapter to the gas-supply stub
using a pipe compound resistant to all gases. Tighten
securely. Then attach the open end of the fl ex connector
to the adapter. Tighten securely. Ensure the pan rests
level on the fi replace fl oor after connection. Adjust the
pan if necessary.
7. LEAK TEST: Be sure the control valve is in the OFF
position. Turn on the fi replace gas supply, and test at
all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present.
Turn off the gas and tighten at all connections. Repeat
until no leaks are present. If a leak persists, turn off
the gas supply and contact the local gas company or
dealer. NEVER USE A FLAME TO CHECK FOR LEAKS.
Turn off the gas supply prior to proceeding.
Important: Heatshields must be in place during operation of the burner system. Overheating of the valve
will cause shut down of the burner system or other operating problems.
Fig. 8-1
Ignitor
Safety (ON/OFF) valve
To gas supply
Thermocouple wire
Spark
wire
Burner pan
Thermocouple
(under screen)
Regulator
Heat shield
(removed)