8. Be sure gas to the fi replace is off. Attach the large
adapter (Item 3A) to the gas-supply stub using a pipe
compound resistant to all gases. Tighten securely.
Then attach the open end of the fl ex connector to
the large adapter. Tighten securely. Ensure the pan
rests level on the fi replace fl oor after connection.
Adjust the pan if necessary.
9. LEAK TEST: Use a long-necked butane lighter, or
lay a lighted match next to the burner pipe, and
carefully turn on the gas supply until the burner
ignites. Test at all connections for leaks using the
appropriate soapy water solution. If bubbles appear,
a leak is present. Turn off the gas and tighten at all
connections. Repeat until no leaks are present. If
a leak persists, turn off the gas supply and contact
the local gas company or dealer. NEVER USE A
FLAME TO CHECK FOR LEAKS.
Turn off the gas supply prior to proceeding.
Fig. 7-1 - Fireplace valve
Fuel injector
Flex
connector
Larger
adapter
Burner
Pan
Gas
supply line
Small
adapter