Owner`s manual
The Real-Fyre
®
burner system has a pilot that can be lit by hand using a match or lighter. When lighting the pilot, follow these
instructions exactly.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the fl oor, as some gas is heavier than
air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try
to repair it. Call a qualifi ed professional service technician. Excessive force or attempted repair may result in fi re or explosion.
WARNING
If you do not follow these instructions exactly, a fi re or explosion may result, causing property
damage, personal injury, or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to
inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
FOR YOUR SAFETY, READ BEFORE LIGHTING
LIGHTING THE PILOT
1. Push in the gas control knob slightly and turn
clockwise
to OFF (Fig. 17-1). Refer to
the PARTS LIST for the location of the burner
control valve knob.
Note: The burner control knob cannot be turned
from PILOT to OFF unless the knob is
pushed in slightly. Do not force.
Wait fi ve minutes to clear out any gas. If you then
smell gas, STOP! Notify your gas supplier or the
fi re department immediately. If you don’t smell gas,
go on to step 2.
2. Turn the burner control knob counter-clockwise
to PILOT (Fig. 17-1). Push the control
knob fi rmly and fully in and hold. Hold a long
fi replace match or lighter near the thermocouple
to light the pilot. Continue to hold the control
knob in for approximately 30 seconds after the
pilot is lit, then release the knob. The pilot will
remain lit.
• If the pilot will not light, repeat steps 1 and 2.
• If the pilot will not stay lit after several tries,
turn the gas control knob to OFF and call your
service technician or gas supplier.
IGNITING THE MAIN BURNER
1. Make sure the pilot is burning.
2. Turn the gas control knob counterclockwise
to ON (
Fig. 17-1) to ignite the burner. The burner
will ignite.
Note: Periodically check the pilot fl ame for the
proper fl ame pattern (
Fig. 17-1).
MAKE SURE THE THERMOCOUPLE AND PILOT
ASSEMBLY ARE IN CORRECT ALIGNMENT WITH
EACH OTHER (
Fig. 17-1).
TURNING OFF THE MAIN BURNER
1. From the ON position, turn the control knob
clockwise
to the PILOT position. The burner
will extinguish, and the pilot will remain lit.
EXTINGUISHING THE PILOT
1. If complete shutdown is desired, from the PILOT
position, push in the control knob slightly and
turn clockwise
to the OFF position. Do not
force the knob. This will require the pilot to be
relit before using the burner again.
17
Thermocouple
Pilot
1. Turn the knob
clockwise to OFF
only when
complete shutdown
is desired or prior to
lighting the pilot.
Fig. 17-1
1. Lighting -Turn the burner control knob
to OFF
and wait 5 minutes before
lighting.
2. Turn knob
counterclockwise
to PILOT position. With
match ready, press
knob in and hold for 60
seconds while lighting
pilot.
3. Turn the knob
counterclockwise
to ON to light the
burner.
PILO T
ON
OFF
OFF
ON
PILOT
OFF
ON
PILOT
OFF
ON
PILOT
Pilot Assembly
LIGHTING INSTRUCTIONS - MANUAL PILOT AND SERIES 17 VALVE
The series 17 valve is capable of remote operation. If this
unit was shipped with a remote, or if a remote system
was installed later, read and follow the separate remote
instructions to operate the burner remotely.
(Manual valve shown)