Owner`s manual
11
The damper clamp with hex bolt (Fig. 11-1) is provided as a means to
prevent full closure of the damper blade. The clamp is easily attached to
most damper blades with pliers or a wrench, and must be permanently
installed. The clamp is designed to prevent accidental closure of the damper
when installed as illustrated (Fig. 11-2 and Fig. 11-3). Should the clamp not
fi t, or fail to provide the permanent vent opening listed in the table found
above, have a permanent stop installed, remove the
damper blade, or have the damper cut to provide
the minimum permanent opening required.
Note: These are minimum damper opening
specifications. The damper must be
completely opened when operating this
gas appliance to achieve the best ventilation
possible.
INSTALLATION
INSTALLING THE BURNER
The Real-Fyre gas log set must be installed by a qualifi ed professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be
sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the
fi replace. Fireplace fl oor must be level, clean, and smooth.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (see Fig. 11-4).
CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall.
3. Attach the nut end of the fl ex connector to the adapter found on the valve or, if attached, on the regulator
behind the valve. Tighten securely.
4. Place the burner system into the fi replace so the open burner pan faces outward.
5. Locate the grate and attach the log locators to the 2 outer bars of the grate with screws and nuts. The
log locators should be loosely positioned toward the middle of the bars with screw slots facing towards
fi replace side walls (Fig. 11-5). Temporarily place the front log at the front of the grate, to correctly
determine the log locator position. Slide the log locators up against the rear of the front log. Tighten
the log locators in place. Remove the front log.
6. Place the grate over the burner pan so the log locator brackets fi t over the back edge of the burner pan
to lock it in position.
7. Center this assembly in the fi replace and place it as far back in the fi replace as possible. Remove the
grate for the gas connection and granule/ember placement.
Fig. 11-5 Log locators on grate
Fig. 11-1
Damper clamp
Set screw
Fig. 11-2 Fig. 11-3
Open
Closed
Fig. 11-4
Gas supply
line stub
Gas line
cap
(Brackets are to fi t over