Owner`s manual
10
Do not use this log set if any part has been
underwater. Immediately call a qualifi ed professional
service technician to inspect the appliance and to
replace any part of the control system and any gas
control which has been underwater.
The gas log set must be isolated from the gas supply
piping system by closing its individual shut-off valve
during any pressure testing of the gas supply system
at test pressures equal to or less than
1
/
2
psig. The
gas log set and its individual shut-off valve must be
disconnected from the gas supply piping system when
testing at pressures in excess of
1
/
2
psig.
Keep the area of the gas log set clear and free from
combustible materials, gasoline, and other fl ammable
vapors and liquids.
FIREPLACE SIZE REQUIREMENTS
Important: For safe operation and proper
performance and to comply with
CSA Certification, ONLY Robert
H. Peterson parts and accessories
must be used with this gas log set.
The minimum inlet gas supply pressure for purpose
of input adjustment is 5" for natural gas and 11" for
propane gas. Maximum inlet gas supply pressure for
this burner is 10.5" for natural and 13" for propane gas.
A fi replace screen must be in place when the
system is burning. Provisions for adequate
combustion air must be maintained. Unless other
provisions for combustion air are provided, the
screen shall have an opening(s) for introduction of
combustion air. Combustion air is adequate when
all fl ames curl into the fi replace and away from the
screen. When a glass fi replace enclosure (door) is
used, leave the doors fully open when the system
is in operation.
The minimum fi rebox dimensions in which log set is
certifi ed to be installed, is listed in the Technical Data
Table here.
Note: For remote ready units, the maximum BTU
thru put of some valves may vary.
Note: The minimum chimney height from hearth to top of chimney is 15'.
THE FOLLOWING LOG STYLES ARE COMPATIBLE WITH THE G45 BURNER SYSTEM:
IMPORTANT
For all valves, the air MUST be purged from the gas line before the pilot will light and burn properly. The time
needed to purge will depend on the length of the gas line to the unit and the amount of time since the unit or gas
line was last used. It may take several minutes before all the air is purged and the pilot will light and burn properly.
Follow the LIGHTING INSTRUCTIONS section in this manual.
RDP: Golden Oak Designer Plus
FO: Forest Oak
FOS: Forest Split Oak
CR: Cedar
ACR: Aged Cedar
RED: Red Oak
S: Split Oak
SDP: Split Oak Designer Plus
RRSO: Rugged Split Oak
WO: Woodland Oak
CHB: Charred Royal English Oak
CHF: Charred Forest Oak
CHN: Charred Northern Oak
NO: Noble Oak
R: Golden Oak
RRO: Rugged Oak
PO: Post Oak
B: Royal English Oak
H: Heritage Oak
CDR: Coastal Driftwood
BD: Royal English Oak Designer
HD: Heritage Oak Designer
W: White Birch
WCF: Western Campfyre
CHD: Charred Oak
CHS: Charred Split
CHRED: Charred Red Oak
CHCR: Charred Cedar
CHACR: Charred Aged Cedar
CHRRSO: Charred Rugged Split Oak
IMPORTANT INFORMATION
* This required width allows for centering of the log set.
Burner
size
Min. Fireplace Dimensions
BTU
Width
Depth Height
Front* Rear NAT. L.P.
16/19" 29" 23" 11" 18" 40k 30k
18/20" 30" 24" 14" 18' 70k 45k
24" 34" 28" 14" 18" 90k 65k
30" 40" 34" 15" 18" 95k 75k
36" 46" 40" 16" 18" 95k 75k
Note: Rear width is at corresponding depth.
Minimum Free Opening Area of Chimney Damper for Venting (sq. in.)
For Factory-Built Fireplaces For Masonry-Built Fireplaces
Chimney
16/19" 18/20"
24"
30" 36" 16/19" 18/20"
24"
30" 36"
15' (min.) 18 33 46 47 47 27 44 55 57 57
20' 15 27 38 41 41 24 40 50 52 52
25' 1323323535-----
30' 12 21 29 32 32 22 36 45 47 47