7. LEAK TEST: Turn on the fi replace gas supply, and test
at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present. Turn
off the gas and tighten at all connections. Repeat until
no leaks are present. If a leak persists, turn off the gas
supply and contact the local gas company or dealer.
NEVER USE A FLAME TO CHECK FOR LEAKS.
Turn off the gas supply prior to proceeding.
Important: Heatshields must be in place during
operation of the gas log set. Overheating of
the valve will cause shut down of the gas
log set or other operating problems.
GRANULE, EMBER, AND GRATE PLACEMENT
GRANULE PLACEMENT
The granules supplied with the unit are specially selected for use with
either propane gas or natural gas. They maximize fl ame distribution
and reduce carbon buildup.
1. Fill the burner pan completely with the granules* (Item 11). See
Fig. 6-2. Avoid spilling the granules on the pilot kit.
*Note: Use only select sand for natural gas burners and vermiculite
for propane gas burners.
2. Slope the granules at the same angle as the burner pan. This is
important to ensure quiet lighting and even fl ame distribution.
3. Pour a small amount of the granules along the outside edges
of the burner pan (Fig. 6-2). This prevents fl ame diversion.
EMBER PLACEMENT
Sprinkle the glowing embers (Item 10) lightly and evenly over the entire surface of the granules (in the pan only).
Break up any clumps that may have developed during shipment.
Important: Do not add any additional embers to this log set. Any additional embers may cause unsafe
operation.
GRATE PLACEMENT
Center the grate over the burner pan.
Fig. 6-1
Ignitor
Safety (ON/OFF) valve
To gas supply
Thermocouple wire
Spark wire
Burner pan
Thermocouple
(underneath)
Heat shield
(removed)
INSTALLATION (cont.)
Fig. 6-2 Granule placement
Burner pan
Granules