Owner`s manual
5
REV 0 - 1012011423
L-A2-298
INSTALLING THE DAMPER CLAMP
INSTALLING THE DAMPER CLAMP
INSTALLATION
The damper clamp with hex bolt (Fig. 5-1) is provided as a means to prevent
full closure of the damper blade. The clamp is easily attached to most damper
blades with pliers or a wrench, and must be permanently installed. The clamp
is designed to prevent accidental closure of the damper when installed as
illustrated (Fig. 5-2 and Fig. 5-3). Should the clamp not fi t, or fail to provide the
permanent vent opening listed in the table found above, have a permanent
stop installed, remove the damper blade, or have the
damper cut to provide the minimum permanent opening
required.
Note: These are minimum damper opening
specifi cations. The damper must be completely
opened when operating this gas appliance to
achieve the best ventilation possible.
Fig. 5-1
Damper clamp
Set screw
Fig. 5-2 Fig. 5-3
Open
Closed
Fig. 5-4
Gas supply
line stub
Gas line
cap
Fig. 5-5 Log locators on grate
INSTALLING THE BURNER
The Real-Fyre gas log set must be installed by a qualifi ed professional service technician. Instructions must
be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be sure the
log set is designed and labeled for the type of gas (natural or propane gas) supplied to the fi replace.
Fireplace fl oor must be level, clean, and smooth.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (see Fig. 5-4).
CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall.
3. Locate the grate (Item 7) and attach the log locators (Item 13) to the 2 outer bars of the grate with screws
and nuts. The log locators should be positioned on the middle of the bars with screw slots facing towards
fi replace side walls (Fig. 5-5).
4. Attach the nut end of the fl ex connector (Item 9) to the adapter found on the valve. Tighten securely.
5. Place the burner pan into the fi replace so that it is centered.
6. Be sure gas to the fi replace is off. Attach the large adapter end of the fl ex connector (Item 9) to the gas-
supply stub using a pipe compound resistant to all gases. Ensure adapter (and nut) are tightened securely.
Ensure the pan rests level on the fi replace fl oor after connection. Adjust the pan if necessary.