Owner`s manual

8
Fig. 8-4- APK 16(P)
Elbow
Aluminum
tubing
Air mixer/fuel
injector
Adapter
Gas-supply line
Remote safety valve
Burner pan
APK- 16 valve
4. Installing the Real-Fyre
®
gas log set using
a Peterson remote safety pilot system (APK
series) APK-10(P), APK-11(P), APK-15(P),
APK-16(P)
Peterson remote systems are designed to
provide the ultimate in convenient and reliable
lighting of the Real-Fyre
®
gas log set. With the
fl ick of a switch or the push of a button, you
can sit back, relax, and enjoy a comforting
fi re. Each APK system includes a control (a
number of options are available), gas valve
(APK valves are CSA and C.G.A. certifi ed
for natural or propane gas), pilot assembly,
heatshield, and APK connector kit.
a. Carefully follow the instructions supplied
with the Peterson remote safety system
for the steps to assemble the remote
system and install it on the burner pan.
b. Carefully turn on the gas supply, ignite
the burner pan, and test for leaks at all
connections with a soapy water solution. If
bubbles appear, a leak is present. Turn off
the gas and tighten all connections, turn on
the gas and repeat the leak test. Repeat
until no leaks are detected. Never use a
fl ame to check for leaks.
c. Turn off the APK system.
d. Proceed to GRANULE PLACEMENT
section of these instructions.
INSTALLING THE REAL-FYRE BURNER
®
SYSTEM (Cont.)
Fig. 8-1 - APK-10(P)
Elbow
Aluminum tubing
Air mixer/fuel injector
Adapter
Gas-
supply
line
Remote safety valve
Burner pan
Note: The heat shield is not
shown, but must be in
place when operating
the gas log set.
APK 10
Valve
Burner
pan
Fig. 8-2 - APK-11(P)
Hearth
elbow
Aluminum tubing
Air mixer/fuel
injector
Burner pan
Gas-supply line
Remote safety valve
APK 11
Valve
Note: The heat shield is not
shown, but must be in
place when operating
the gas log set.
Fig. 8-3 - APK 15(P)
Elbow
Aluminum
tubing
Air mixer/fuel
injector
Adapter
Gas-supply line
Remote safety valve
Burner pan
APK- 15 Valve
Note: The heat shield is not
shown, but must be in
place when operating
the gas log set.
Note: The heat shield is not
shown, but must be in
place when operating
the gas log set.