Owner`s manual

7
INSTALLING THE REAL-FYRE
®
BURNER SPK SYSTEM (Cont.)
e. Use a long-necked butane lighter,
or lay a lighted match next to the
burner pipe and carefully turn on the
AV valve until the burner ignites.
f. Test for leaks at all connections with
a soapy water solution. If bubbles
appear, a leak is present. Turn off
the gas and tighten all connections,
then turn on the gas and repeat the
leak test. Repeat until no leaks are
detected. Never use a flame to
check for leaks.
g. Turn off the AV valve.
h. Proceed to GRANULE
PLACEMENT section.
3. Installing the Real-Fyre
®
gas log set
using a Peterson manual safety pilot
system (SPK series) (Fig. 7-1 &
Fig. 7-2)
The Peterson SPK control systems makes
enjoying the Real-Fyre
®
gas log set
convenient and trouble-free. Just a turn
of the knob (SPK-20, SPK-26, SPK-32,
or SPK-33) or steel rod handle (SPK-21)
allows you to easily ignite or extinguish
the log set. The SPK series is available for
natural or propane gas and will continue to
operate during power failures, as it requires
no outside source of electricity to operate.
The valve is CSA certifi ed, and the standing
pilot is adjustable. The built-in safety feature
automatically shuts off the gas fl ow should
the pilot go out. A convenient pressure tap
is included for easy gas pressure testing.
Advanced heat shielding adds greater
heat protection for cooler, long-lasting
operation.
L
0
F
F
O
N
P
I
L
O
T
Fig. 7-2 - SPK-26 system
SPK valve
Elbow
Aluminum tubing
Gas-supply line
Fuel injector
SPK -26
SPK valve
Fig. 7-1 - SPK-20 system
Note: The heat shield is not
shown, but must be in
place when operating
the gas log set.
Elbow
Aluminum tubing
Burner pan
Gas-supply line
Fuel injector
SPK valve
SPK
Valve
Brass
adapter
Pressure
tap
SPK 20
Burner pan