Owner`s manual

6
Check to see if the burner fuel injector or air mixer
is installed on the side of the burner closest to the
gas connection. The fuel injector or air mixer may be
mounted at either end of the burner pan. Be sure the
opposite end is capped tightly.
The Real-Fyre
®
gas log set can be installed using a
number of valve options. Proceed to the appropriate
section identifi ed with the valve option you are using:
1. Installing the Real-Fyre
®
gas log set
using the valve supplied with fireplace
(Fig. 6-1)
a. Attach the hearth elbow to the gas-supply
stub in the fi replace. Use Tefl on tape or pipe
compound on the stub. Tighten securely.
b. Attach the smaller connector elbow to the
fuel injector or air mixer on the burner pan.
Use Tefl on tape or pipe compound. Tighten
securely.
c. Connect the hearth elbow to the connector
elbow with the aluminum tubing. Tighten both
ends securely.
d. Use a long-necked butane lighter, or lay a lighted
match next to the burner pipe and carefully turn
on the gas supply until the burner ignites.
2. Installing the Real-Fyre
®
gas log set using a
Peterson manual on/off system (AV series)
(Fig. 6-2)
The AV series is an on/off control system for use in
a fi replace not supplied with its own valve. The solid
brass valve is CSA certifi ed. The AV-17 has a knob
handle and extension; the AV-18 has a steel rod
handle. This system requires a match or long-necked
butane lighter to manually ignite the log set.
a. Attach the hearth elbow to the gas-supply
stub in the fi replace. Use Tefl on tape or pipe
compound on the stub. Tighten securely.
b. Attach the AV valve to the fuel injector or air
mixer on the burner pan using the
3
/
8
" elbow
supplied with the AV valve. Use Tefl on tape or
pipe compound. Tighten securely.
c. Discard the connector elbow of the connector
kit. Be sure the fl ared adapter supplied with
the AV valve is securely attached to the inlet
side of the valve. Connect the hearth elbow to
the fl ared adapter with the aluminum tubing.
Tighten both ends securely.
d. Turn off the AV valve and turn on the gas supply
to the fi replace.
e. Test for leaks at all connections with a soapy
water solution. If bubbles appear, a leak
is present. Turn off the gas and tighten all
connections, then turn on the gas and repeat
the leak test. Repeat until no leaks are detected.
Never use a fl ame to check for leaks.
f. Turn off the gas supply.
g. Proceed to GRANULE PLACEMENT section.
To light the gas log set, carefully follow the operating instructions supplied with the
Peterson manual safety pilot kit or Peterson remote safety system.
Note: We recommend that before you install the log set, you familiarize yourself with the control valve
layout. This will help you to be confi dent operating the log set when fully installed (see fi gures
below for typical control positions).
Fig. 6-2 - AV series
Hearth
elbow
Aluminum tubing
Air mixer/ fuel injector
Gas supply line
Flared
adapter
AV-17 or AV-18 valve
Burner pan
Fig. 6-1 - Fireplace valve
Connector
elbow
Hearth
elbow
Aluminum tubing
Air mixer/fuel injector
Burner pan
Gas-supply line
Section 1 Fireplace valve
Manual On/Off
Valve
Section 2 AV Series
Manual Safety Pilot
System
Section 3 SPK Series
Manual Safety Pilot
System
Section 4 APK Series
Remote Safety Pilot
System
INSTALLING THE OPTIONAL REAL-FYRE
®
BURNER SPK & APK SYSTEMS