Owner`s manual
5
L-A2-013
REV 5 - 1011081109
INSTALLATION
The damper clamp with hex bolt (Fig. 5-1) is provided as a means to prevent
full closure of the damper blade. The clamp is easily attached to most damper
blades with pliers or a wrench, and must be permanently installed. The clamp
is designed to prevent accidental closure of the damper when installed as
illustrated (Fig. 5-2 and Fig. 5-3). Should the clamp not fi t, or fail to provide the
permanent vent opening listed in the table found above, have a permanent
stop installed, remove the damper blade, or have
the damper cut to provide the minimum permanent
opening required.
Note: These are minimum damper opening
specifi cations. The damper must be completely
opened when operating this gas appliance to
achieve the best ventilation possible.
Fig. 5-1
Damper clamp
Set screw
Fig. 5-2 Fig. 5-3
Open
Closed
INSTALLING THE BURNER
The Real-Fyre gas log set must be installed by a qualifi ed professional service technician. Instructions must
be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be sure the
log set is designed and labeled for the type of gas (natural or propane gas) supplied to the fi replace.
Fireplace fl oor must be level, clean, and smooth.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS. If your burner is to be installed
with a pilot kit; carefully follow the instructions supplied with your pilot kit for specifi c gas connection.
The burner pan is supplied with an air mixer for propane gas or a fuel injector for natural gas. The air mixer / fuel
injector must be used in ALL installations. The air mixer / fuel injector has a precisely sized orifi ce to ensure
only the proper quantity of gas enters the burner. This allows maximum performance and gas conservation.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (see Fig. 5-4).
CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall.
3. Attach the small adapter (Item 9C) to the fuel injector / air mixer on the burner pan, using a pipe compound
resistant to all gases. Tighten securely. DO NOT REMOVE THE FUEL INJECTOR / AIR MIXER. Then
attach one end of the fl ex connector (Item 9B) to the small adapter. Tighten securely.
4. Place the burner system into the fi replace so the open burner pan faces outward.
5. Locate the grate (Item 13) and attach the stabilizer clips (Item 7) to the 2 outer bars of the grate with screws
and nuts. The stabilizer clips should be positioned towards the middle of the bars (Fig. 5-5). Place a clip
on each side of the bar, insert the screw, attach the nut, and loosely tighten. Repeat for the other side.
6. Place the grate over the burner pan so the stabilizer clips fi t over the back edge of the burner pan to lock
it in position. Completely tighten the clips in place.
GRATE
BURNER PAN
STABILIZER
CLIPS
BACK
WALL OF
FIREPLACE
Fig. 5-5 Stabilizer clips on grate
Fig. 5-4
Gas supply
line stub
Gas line
cap