Owner`s manual

7
L-A2-102
Rev 8 - 1501081400
INSTALLATION (Cont.)
CONNECT TO GAS SUPPLY
To connect the valve to the gas supply, the fl ex connector
kit and component parts will be needed, which are included
with the burner system. Refer to the PARTS LIST in the
instructions supplied with the burner to identify the key
parts needed.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS
TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and
remove the cap, if attached.
CAUTION: When removing the cap, make sure the stub
does not turn, loosening the connection inside
the wall.
3. Discard the small adapter included with burner fl ex
connector kit. Attach one end of the fl ex connector
(included with burner) to the elbow found on the control
valve. Tighten securely. See Fig. 7-1.
4. Place the burner system in the fi replace. Center the
burner in the fi replace.
5. Be sure gas to the fi replace is off. Attach the large
adapter (included with burner fl ex connector kit) to
the gas-supply stub using a pipe compound resistant
to all gasses. Tighten securely. Then attach the open
end of the fl ex connector to the large adapter. Tighten
securely.
6. LEAK TEST: Turn on the fi replace gas supply, and test
at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present.
Turn off the gas and tighten at all connections. Repeat
until no leaks are present. If a leak persists, turn off
the gas supply and contact the local gas company
or dealer. NEVER USE A FLAME TO CHECK FOR
LEAKS.
7. Follow the instructions supplied with the Peterson
burner system for any additional requirements
regarding specifi c burner setup and placement.
Fig. 7-1 Install fl ex connector to valve
Attach fl ex connector
to elbow on valve
To large adapter /
gas supply