Owner`s manual

7
L-A2-10208
Rev 3 - 0801151103
INSTALLING OR REPLACING BATTERIES FOR
THE IGNITION MODULE PACK
Two 1.5-volt (D-cell) alkaline batteries come supplied with
the EPK-1(M)(P). To install or replace batteries, remove the
green ignition module pack (Item #3), held in place with a
Velcro strip, from rear of the pine cone receiver (Item #9).
Remove battery holder and, where installed, old batteries
(Item #11) from the pine cone. Install new batteries, making
sure they are correctly positioned according to the diagram
inside the battery holder (i.e., the fl at part of the battery
marked "-" on the spring). Replace holder, pressing fi rmly
against the Velcro strip. Replace ignition pack and press
rmly into place. The ignition system is now ready to operate.
Note: For the EPK-1(M)(P) system to work properly,
it is suggested that you replace the batteries
annually with fresh batteries. Always replace
both batteries at the same time.
HEAT SHIELD PLACEMENT
Cover the EPK-1(M)(P) safety valve with the heat shield
as shown in Fig. 7-2. The heat shield must remain in place
over the valve at all times during operation. Keep the area
above the heat shield clear of logs or any other object (Fig.
7-3). Follow the log placement instructions that came with
the burner exactly. Failure to follow these instructions
will cause overheating in EPK-1(M)(P) safety valve
components, resulting in system shutdown.
CAUTION: DO NOT place the EPK-1(M)(P) wire
bundles on, under, or near the heat shield,
burner, or valve. See Fig. 7-4 for example
placement.
PINE CONE PLACEMENT
The designer pine cone incorporating the control switch
is aesthetically designed and is an integral part of the
operation of the EPK-1(M)(P).
The pine cone may be placed in any desired location
on the valve side of the burner as long as it is always
at least 4" from the fl ame and the wire bundle remains
clear of the burner, valve, and heat shield at all times.
See Fig. 7-4 for example placement.
Note: Coil excess wire underneath the pine cone.
CAUTION: THE PINE CONE MAY BE HOT DURING
AND AFTER OPERATION.
Fig. 7-3
INSTALLATION (Cont.)
IMPORTANT
TURN ON THE GAS AND CHECK ALL
CONNECTIONS FOR GAS LEAKS USING A
SOAPY WATER SOLUTION. NEVER USE AN OPEN
FLAME TO CHECK FOR GAS LEAKS. IF LEAKS
ARE PRESENT, TIGHTEN DOWN CONNECTIONS
UNTIL NO MORE LEAKS ARE DETECTED.
Heat
shield
Flame
diverter
bracket in
place
Valve
heat shield
in place
Fig. 7-2
Burner pan
Velcro
strips
ON/OFF
Switch
Battery
pack
Ignitor pack
Pine
cone
Fig. 7-1
ON/OFF
switch
Velcro
strips
Wire bundles go around the
valve and away from the
burner. Coil excess wire under
pine cone switch.
Fig. 7-4
Valve wire
bundle
Pilot
wire
bundle
Pine cone
switch
Valve and heat shield
Burner pan
Keep
area
above
valve
clear