Owner`s manual

6
Real-Fyre gas log sets must be installed only in a wood burning fi replace with the minimum fi rebox
dimensions and venting requirements met (see table on this page). This appliance is designed to burn with
yellow fl ames; adequate ventilation is absolutely necessary.
Burner
Model
Minimum Fireplace Size BTU Rating
Width
Depth Height Natural Gas Propane Gas
Front Rear
G21-GL-18C-12(M)(P) 22" 16" 10" 15" 30k 27k
G21-GL-24C-12 (M)(P) 28" 21" 11" 15" 35k 30k
G21-GL-30C-12 (M)(P) 34" 28" 11" 15" 40k 35k
SPECIFICATIONS
DAMPER CLAMP INSTRUCTIONS
The damper clamp with hex bolt (Fig. 6-2) is provided as a means to prevent
full closure of the damper blade. The clamp is easily attached to most damper
blades with pliers or a wrench, and must be permanently installed. The clamp
is designed to prevent accidental closure of the damper when installed as
illustrated (Fig. 6-3 and Fig. 6-4). Should the clamp not fi t, or fail to provide the
permanent vent opening listed in the table found above, have a permanent
stop installed, remove the damper blade, or have
the damper cut to provide the minimum permanent
opening required.
Note: These are minimum damper opening
specifi cations. The damper must be completely
opened when operating this gas appliance to
achieve the best ventilation possible.
Fig. 6-2
Damper clamp
Set screw
Note: The minimum chimney height from hearth to top of chimney is 15'.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fi replaces For masonry-built fi replaces
Chimney
height
18" 24" 30" 18" 24" 30"
15' 19 22 25 23 26 29
20' 17 20 23 21 24 27
25' 16 19 22 -- -- --
30' 15 18 20 19 22 24
Fig. 6-3 Fig. 6-4
Open
Closed
Note: Rear width is at corresponding depth.