Owner`s manual
24
TROUBLESHOOTING (Cont.)
HIGH CO - CARBON MONOXIDE DETECTORS IN HOME TURNING ALARM ON
A. High CO levels A. TURN OFF UNIT IMMEDIATELY.
B. Call a qualifi ed professional service technician or your gas supplier.
CONDENSATION
A. High room humidity and cold walls or windows will
create condensation in room
A. Open a window or damper slightly.
LOW FLAME HEIGHT
A. Low gas pressure A. Check gas pressure (see Section 1, A1 of this table).
B. Propane tank running low B. Fill tank completely.
BURNER NOT BURNING EVENLY
A. Top burner lights; bottom burner has delayed
ignition or does not light
A1. Check gas pressure. Can be caused by too small of a gas line
(see Section 1, A1 of this table).
A2. Low propane fuel gas level. Vacuum burner tube for soot blockage
and fi ll propane tank.
A3. Flash tube (if present) blocked. Clear blockage.
B. Burner orifi ce(s) clogged B. Clean burner orifi ce(s).
NO SPARK AT ODS PILOT WHEN IGNITOR IS PRESSED / TURNED
A. Ignitor electrode wire loose A. Check wiring and reconnect any loose wiring
B. Ignitor electrode positioned incorrectly B. Contact your dealer for service
ODORS
A. New burner system (break-in period) A. Burn unit for four to six hours with damper, doors, or windows open.
Allow odors to dissipate.
B. Odors created by aerosol sprays, detergents,
household chemicals, and insecticides
B. When these odors are drawn into the fi replace, this may cause
objectionable odors. Thoroughly ventilate the area before restarting
your burner system.
C. Gas leak C. Locate gas leak and correct all leaks.
D. New home, new carpet, or new paint D. When these odors are drawn into the fi replace, this may cause
objectionable odors. Thoroughly ventilate the area before restarting
your burner system.
POSSIBLE CAUSE SOLUTIONS
ODS PILOT WILL NOT LIGHT
A. ODS pilot fl ame lifting off thermocouple/generator A. Check gas pressure (see Section 1, A1 of this table).
B. Piezo spark not lighting ODS pilot B. Check to make sure piezo is sparking when pressing / turning
ignitor. (Note: You may need to press / turn ignitor several times
to ignite ODS pilot.) See LIGHTING INSTRUCTIONS section.
C. Gas supply off/manual shutoff valve closed C. Turn on gas supply or open manual shutoff valve.
D. Air in gas line D. Hold control knob to bleed the line and repeat LIGHTING
INSTRUCTIONS until air is removed.
2)
3)
4)
5)
6)
7)
8)
A. Burner orifi ce(s) clogged
A. Clean burner orifi ce(s).