Owner`s manual
16
NATURAL GAS PROPANE GAS
Outlet pressure reading:
(Flame adjustment on high)
3.5" w.c.
Outlet pressure reading:
(Flame adjustment on high)
10" w.c.
Inlet pressure reading
Max. 10.5" w.c.
Min. 5" w.c.
Inlet pressure reading
Max. 13" w.c.
Min. 11" w.c.
Check the valve regulator pressure at the pressure inlet point.
Turn the inlet screw counterclockwise 2 or 3 turns and then
place the tubing of the pressure gauge over the pressure
inlet point. (The test “inlet” tap is marked IN.) After taking
the pressure reading, turn the inlet screw clockwise fi rmly to
reseal. Do not over-torque. Check for gas leaks.
Note: Gas pressure should be checked after connecting the
gas and prior to any further installation.
GAS PRESSURE SPECIFICATIONS
Fig. 16-3 Control valve
Inlet
Outlet
CHECKING GAS PRESSURE