Owner`s manual

14
BURNER INSTALLATION (cont.)
Important: When the burner system is installed
outdoors, ensure it is not directly exposed to
the elements (precipitation, rain, wind, etc.).
REFER TO THE BURNER PARTS LIST WHEN FOLLOWING
THESE INSTRUCTIONS.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS
TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and
remove the cap, if attached (reference Fig. 14-1).
CAUTION: When removing the cap, make sure the stub does
not turn, loosening the connection inside the wall.
3. Place the burner system in the fi replace. Center the burner
in the fi replace. (Reference Fig. 14-2 for orientation.)
4. Be sure gas to the fi replace is off. Remove the adapter
that is loosely connected to the fl ex connector (coming off
of the burner system). Attach the adapter to the gas-supply
stub using a pipe compound resistant to all gasses. Tighten
securely. Then attach the open end of the fl ex connector
to the adapter. Tighten securely. (See Fig. 14-1.)
5. LEAK TEST: Turn on the fi replace gas supply, and test
at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present. Turn
off the gas and tighten at all connections. Repeat until
no leaks are present. If a leak persists, turn off the gas
supply and contact the local gas company or dealer.
NEVER USE A FLAME TO CHECK FOR LEAKS.
6. The burner system must be secured to the fi replace fl oor.
The unit has two anchoring tabs located at the bottom
front . With the unit centered, mark and then drill two
1
/
4
"
pilot holes .
7. Reposition the burner over the pilot holes and insert the
provided hammer screws. Carefully hammer the screws
in as shown in Fig. 14-3.
8. Use a power drill to complete the fastening of the screws
(Fig. 14-4).
Note: Should the burner need to be removed for
servicing; rst unfasten the screw, then use a fl at
head screwdriver to pry up the anchoring tab until
the wedge anchor pops out. See Fig.14-5. The screw
assembly is reusable.
Fig. 14-3 Installing hammer screws
Fig. 14-4 Fastening hammer screws
Fig. 14-5 If removal is required
A
(Remove)
B
(pry up)
Fig. 14-1 Connect gas supply
Fig. 14-2 Overall orientation (24" shown)
Flex connector
Adapter
Gas supply stub