1. Locate your Series 12 control valve (p. 15). Turn the
control knob (Fig. 31-4) from the OFF position (see
Fig. 31-1) slightly counterclockwise to PILOT
(see Fig. 31-2). Press the control knob in and hold
for 10 seconds (only pilot gas will fl ow). Continue
pressing control knob and push the piezo ignitor (see
Fig. 31-4). You should hear a click, and pilot should
light. Repeat this step until the pilot lights. Continue
to hold the control knob in the PILOT position for 30
seconds after the pilot has been lit.
2. The pilot flame should now remain lit. It should
always be present when the unvented gas log set
is in operation and should just envelop the tip of
thermocouple. If pilot light goes out, repeat step 1.
If pilot will not stay lit after several tries, follow the
instructions TO TURN OFF GAS TO APPLIANCE in
your Owner’s Manual and call your service technician
or gas supplier.
3. When the pilot fl ame is stable (remains lit), release
the control knob and turn counterclockwise
to
the ON position (see Fig. 31-3) (at stop).
4. To ignite main burner, move burner ON/OFF toggle switch
(see Fig. 31-4) to ON (up). Main burner will ignite.
ON POSITION
READ SETTING
HERE
OFF POSITION
READ SETTING
HERE
PILOT POSITION
READ SETTING
HERE
Fig. 31-3
Fig. 31-1
Fig. 31-2
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage,
personal injury, or loss of life.
HI/LOW
Fig. 31-5
CONTROL KNOB
(ON/OFF/PILOT)
FLAME HEIGHT
KNOB (HI/LOW)
PIEZO IGNITOR
BURNER ON/OFF
SWITCH
Fig. 31-4
The fl ame height and heat output of your log set can
be adjusted by turning the fl ame height knob (see
Figs. 31-4, 31-5) to HI or LO as you wish to reach
your desired heat level/fl ame height. When you are
fi nished enjoying your log set, simply move the burner
toggle switch to OFF (down). In this position, the pilot
will remain lit, and the log set can be relit by moving
the switch to ON.
If you do not plan on using your log set for an extended
period, you may elect to extinguish the pilot. To do this,
move the toggle switch to OFF, then rotate the control
knob clockwise
, depressing the knob slightly as
you pass PILOT, to the OFF position (a stop). This
will require that you relight the pilot before you use
the log set again.
Note: When completely shutting your log set
down, be sure to TURN THE FLAME FULLY
OFF (turn from ON through PILOT to OFF).
Make sure the burner is completely off for 1
minute before relighting!
If this unit was shipped with a remote, or if a
remote system was installed later, read and
follow the separate remote instructions to
operate the burner remotely.
LIGHTING INSTRUCTIONS FOR THE G18-12 (M)(P) BURNER SYSTEM
OPERATING THE LOG SET - LIGHTING AND EXTINGUISHING (Cont.)
OFF position
PILOT position ON position
Read setting here
Read setting here
Read setting here
Control knob
ON/OFF/PILOT
Flame height knob
HI/LO
Piezo ignitor
Burner
ON/OFF switch
HI/LO