Owner`s manual

28
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result, causing
property damage, personal injury, or loss of life.
LIGHTING INSTRUCTIONS - 01V(P) VALVE
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional
service technician to inspect the appliance and to replace any part of the control system and any gas control
that has been underwater.
LIGHTING THE ODS PILOT
1. Locate your electronic control valve (see PARTS LIST,
Item 2). Turn the control arrow to MAN for manual
mode (see Fig. 28-1).
2. Press the ON/OFF switch from O to I (see Fig. 28-1).
Using a small bladed screwdriver or similar, press and
hold the button within the hole on the control (see Fig.
28-2). Using a long-neck butane lighter, ignite the
ODS pilot fl ame. Hold in the button for about 1 minute
(or longer if fi rst use or after a long period of non-use).
3. The ODS pilot fl ame should now remain lit. It should
always be present when the gas log set is in operation
and just envelop the tip of thermocouple. If the ODS pilot
light goes out, repeat steps 1-2. If the ODS pilot will not
stay lit after several tries, follow the instructions TO TURN
OFF GAS TO APPLIANCE in your owner’s manual and
call your service technician or gas supplier.
IGNITING THE MAIN BURNER
1. When the ODS pilot fl ame is stable (remains lit,
beeping stops), turn the control knob to ON. Turn
the fl ame height control knob counterclockwise
past ON; gas will fl ow to the main burner, and the
main burner will ignite. The ember burner will ignite
shortly afterward.
ADJUSTING THE FLAME HEIGHT
1. To adjust the fl ame height, turn the fl ame height
control knob (see Fig. 28-3) until the desired fl ame
height is reached (counterclockwise to increase,
clockwise
to decrease).
2. To turn off just the main burners, turn the fl ame
height control knob fully clockwise until fl ame is
extinguished. The ODS pilot fl ame will remain lit.
SHUTTING OFF THE ODS PILOT
If you do not plan on using your log set for an extended
period you may elect to extinguish the ODS pilot. To
do this, press the I/O switch on the valve to O. This will
completely shut down the log set (main burners and ODS
pilot will extinguish). This will require that you relight the
ODS pilot before you use the log set again. To do so, follow
steps 1-2 above. Always turn fl ame height control knob
to the OFF position when shutting it down.
Note: When completely shutting your log set down,
be sure to TURN THE (I/O) SWITCH ON THE
VALVE TO O (OFF). Make sure the burner is
completely off for 1 minute before relighting!
To operate the burner using a remote handset and
receiver, follow the instructions supplied with the
remote.
CHECKING THE ODS PILOT FLAME
1. The ODS pilot fl ame must be present when the burner
is operating. The fl ame should touch the top of the
thermocouple tip (Fig.
28-4).
2. If the ODS pilot fl ame does not touch the top of
the thermocouple tip, then the main burner will not
function properly (see Fig.
28-5 for incorrect ODS
pilot fl ame).
3. With the burners off, the ODS pilot fl ame off, and the
assembly cool, check the burner assembly, air intake
opening on the ODS pilot, and air shutter openings
on the burner for any blockages that could affect the
operation of the ODS pilot fl ame.
FOR YOUR SAFETY, READ BEFORE LIGHTING
Fig. 28-3
When the ODS pilot
is stable, turn flame
height control knob
counterclockwise to ignite
burner. Adjust for fl ame
height as desired.
Fig. 28-4
Correct ODS pilot fl ame
ODS PILOT FOR REMOTE VALVES
(NG shown)
Fig. 28-5
Incorrect ODS pilot fl ame
ON/OFF
switch
Turn arrow
to MAN
Press & hold
button at bottom
of hole
Fig. 28-1 Fig. 28-2
Flame
touching
Thermocouple
Flame not
touching
Thermocouple
The Real-Fyre
®
burner system has an ODS pilot. When starting the ODS pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the gas burner system area for gas. Be sure to smell next to the fl oor, as some gas is
heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON PAGE 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't
try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.