Owner`s manual
20
EMBER PLACEMENT
The glowing embers are supplied in the larger of the two ember bags containing the darker embers (Fig. 20-2). It is
important that only the embers supplied be used and that no additional glowing embers be added. Open the bag
and spread the embers loosely along the entire length of the ember burner (Fig. 20-3) from left to right on
the burner and on the vertical portion of the ember burner. Break up any clumps that may have developed
IMPORTANT
For all valves, the air MUST be purged from the gas line before the ODS pilot will light properly. The time taken to do this
will depend on the length of gas line from the meter to the unit and the length of time since the unit or gas line was last
used (in the case of non-use during warm weather for example). It may take from 3-15 minutes before all the air is purged
and the ODS pilot will light properly. This is done using the method for lighting the ODS pilot, but holding in the control
valve for a longer period. Follow the relevant LIGHTING INSTRUCTIONS in this manual for the specifi c valve type.
INSTALLATION - GRANULE, EMBER AND LOG PLACEMENT
LAVA GRANULE PLACEMENT
Lava granules are provided as an aesthetic enhancement to the G10 vent-free
gas log set.
Spread the lava granules on the fl oor of the fi rebox around the front and the sides
of the vent-free gas log set (Fig. 20-1).
BE SURE THAT NO GRANULES ENTER THE MAIN BURNER OR INTERFERE
WITH THE BURNING OF THE LOG SET.
Fig. 20-1
LOG PLACEMENT
2
1
5
3 4
NOTE: DO NOT COVER BURNER PORTS
WITH LAVA ROCK; USE THE
SUPPLIED EMBERS ONLY
Fig.
20-3
Fig. 20-2
WARNING
Failure to position the
parts in accordance
with these diagrams or
failure to use only parts
specifi cally approved with
this heater may result
in property damage or
personal injury.
Carefully follow the detailed instructions on
the next page for correct log placement.
Fig. 20-4
Fig. 20-6
Fig. 20-5
during shipment and make sure the embers are
spread evenly over the entire area. Failure to follow
these instructions will result in unsafe operation.
BRYTE COALS PLACEMENT
With the glowing embers spread evenly across the
entire length of the ember burner, open the bag of
bryte coals containing a smaller amount of the lighter
colored embers (Fig. 20-4) and pinch off (Fig. 20-5) six
(6) one inch (1") pieces of the bryte coals. Place the six
(6) pieces on top of the glowing embers in the spots
shown in Fig. 20-6.
DO NOT ADD ANY ADDITIONAL
EMBERS TO THIS LOG SET. ANY
ADDITIONAL EMBERS OR BRYTE
COALS MAY CAUSE UNSAFE
OPERATION.