Owner`s manual

18
INSTALLATION
IMPORTANT
For all valves, the air MUST be purged from the gas line before the ODS pilot will light properly. The time taken to do
this will depend on the length of gas line from the meter to the unit and the length of time since the unit or gas line
was last used (in the case of non-use during warm weather for example). It may take from 3-15 minutes before all
the air is purged and the ODS pilot will light properly. This is done using different methods, depending on which valve
is fi tted to the unit. Follow the relevant LIGHTING INSTRUCTIONS in this manual for the specifi c valve type.
CONTROL SETTINGS
We recommend that before you install the log set you familiarize yourself with the control valve layout. This
will help you to be confi dent operating the log set when fully installed. See the fi gures below for typical control
positions.
Fig. 18-4
OFF IGNITION PILOT ON
15 SERIES REMOTE GAS VALVE
OPERATING POSITIONS
OFF PILOT ON
Read setting here
12 SERIES REMOTE GAS VALVE
OPERATING POSITIONS
Fig. 18-3
OFF
PILOT ON
ON
Fig. 18-5
Valve switch
set to O
Flame control
turned OFF
Valve switch
set to I
Flame control
turned OFF
Valve switch
set to I
Flame control
turned ON
OFF PILOT ON/ HIGH ON/ LOW
MANUAL GAS VALVE
OPERATING POSITIONS
Fig. 18-2
Fig.
18-1
01V SERIES REMOTE GAS VALVE
OPERATING POSITIONS
hole containing switch
A. G10-16/18(P) - Hold in control knob at PILOT (see Fig. 18-2).
B. G10-16/18-12(M)(P) - Hold down control knob at PILOT (see Fig. 18-3).
C. G10-16/18-15(M)(P) - Hold in control knob at PILOT (see Fig. 18-4).
D. G10-16/18-01V(P) - Set control to manual. Press O/I to I (see Fig. 18-5 ).
Use a pen tip to activate the switch inside the hole as shown in Fig. 18-1.