Owner`s manual
6
LISTING AND CODE APPROVALS
LISTING
This direct vent insert has been certifi ed to:
VENTED GAS FIREPLACE HEATER ANSI Z21.88-2009, CSA 2.33-2009
It has been certifi ed for use with either natural or propane gas, and is approved for installation in bedrooms and
aftermarket manufactured (mobile) homes.
CODE REQUIREMENTS
A. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
B. Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier.
Dégagement conforme aux codes d’installation locaux et aux exigences du foumisseunde gaz.
C. A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable,
the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped
Recreational Vehicles and Mobile Housing, CSA Z240.4.
D. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
E. To comply with certifi cation, and building code acceptances, and for safe operation and proper performance
of this appliance, use ONLY Peterson parts and accessories. Use of other controls, parts, and accessories
that are not designed for use with Real Fyre direct vent inserts is prohibited and will void all warranties,
certifi cations, and building code approvals, and may cause property damage, personal injury, or loss of life.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
This appliance is approved for installation in the state of Massachusetts subject to the following requirements:
A. Install this appliance in accordance with 248 C.M.R., the Rules and Regulations Governing Plumbers and
Gas Fitters.
B. The installer or service agent must be a plumber or gas fi tter licensed in the Commonwealth of Massachusetts.
C. The fl exible gas line connector used must not exceed 36 inches (92 centimeters) in length.
D. The individual manual shut-off must be a T-handle type valve, listed and approved by the state of Massachusetts.