Owner`s manual

23
INSTALLATION
INSTALLATION MUST BE DONE BY A QUALIFIED
PROFESSIONAL SERVICE TECHNICIAN.
Important: All requirements in the INSTALLATION
REQUIREMENTS section must be observed and
met, prior to proceeding with installation.
WARNING: Failure to position the parts in accordance with
these diagrams or failure to use only parts
specifi cally approved with this appliance may
result in property damage or personal injury.
BEFORE YOU BEGIN
Confi rm the fi replace accommodates the unit and that all
dimensions are met. Reference the SPECIFICATIONS AND
DIMENSIONS section.
Ensure the fi replace hearth remains clear to allow for the unit to
be installed without any obstructions. This includes all electrical
and gas supply installations in the fi replace.
All plumbing/wiring must be routed along the rear and/or
sides of the unit, NEVER ABOVE OR BELOW.
If required, non-combustible material (such as bricks) may be
placed on the fi replace oor to elevate the unit to the appropriate
location in the fi replace.
GAS SUPPLY SETUP
A left-side install is shown here, as the unit's valve is located
on the left side. Your individual installation may vary. Observe
all local codes.
1. Route the gas supply into the left side of the fi replace.
2. It is recommended that a gas shut-off valve (not included)
be attached to the gas supply stub. Use a pipe compound
resistant to all gasses. See Fig 23-1.
Note: A
3
/
8
" C.S.A. stainless steel flex connector (not
included) will be required. The fl ex will be connected
at a later time, when the insert is ready to be
installed.
ELECTRICAL SETUP
A 120VAC (15 AMP minimum) Ground Fault Circuit
Interrupter (GFCI) GROUNDED 3-wire receptacle (not
included) is required within the vicinity of the fi replace to provide
power to the unit. A left-side install is shown here, as the unit's
power supply cord is located on the left side. Your individual
installation may vary. Observe all local codes.
1. Wire the receptacle into the left side of the fi replace (see
Fig 23-2).
Verify proper polarity of the receptacle.
If an extension cord is used, ensure it is a 3-wire
GROUNDED cord. DO NOT use 2-prong adapters.
DO NOT TAMPER WITH THE EXTENSION CORD OR
THE INSERT POWER-SUPPLY CORD.
Fig. 23-1 Route gas supply
Maintain clearance
for direct vent insert
Gas
supply
Shut-off valve
(not included, recommended)
Fireplace
oor
Fig. 23-2 Install electrical (receptacle)
Maintain clearance
for direct vent insert
DO NOT SLIDE IN THE INSERT, OR CONNECT IT TO THE GAS AND ELECTRICAL AT THIS TIME.
Fig. 23-3 Electrical setup detail
3-wire GROUNDED
cord from unit
(reference only, DO NOT
connect cord at this time)
120VAC (15 AMP minimum) GFCI
GROUNDED 3-wire receptacle
120VAC (15 AMP minimum) GFCI
GROUNDED 3-wire receptacle