Owner`s manual

22
INSTALLATION REQUIREMENTS (cont.)
VENTING REQUIREMENTS (cont.)
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
Below are diagrams of a generic installation for the RHP approved installation method.
This section is just an overview, refer to the INSTALLATION section for complete installation details.
The RHP direct vent insert is ONLY approved for installation using the venting system confi guration
illustrated below:
Termination Cap
(Simpson Dura Vent
#46DVA-CL33)
3" Flexible
vent pipe
(Intake)
3" Flexible
vent pipe
(Exhaust)
Vent
Adapter
Max. Ht. 40'
Min. Ht. 10'
Insulation
Insulation
Insulation in fi replace:
ash trap, gas line access, holes,
any air openings, etc.
Flashing (sealant OK)
This appliance must use its own separate vent system.
The vent system must be vented directly to outside of building.
Ensure exhaust pipe connects to exhaust port of termination cap and exhaust port of vent adapter.
Ensure intake pipe connects to intake port of termination cap and intake port of vent adapter.
DO NOT crimp, rupture, or collapse pipes when routing through any fi replace contours.
Keep pipes as STRAIGHT as possible.
Ensure pipes pass through fi replace damper area. Remove damper.
Carefully read all instructions included with venting kit.
Each installation requires burner air shutter adjustment to ensure optimal fl ame appearance (see SERVICING
AND CLEANING - AIR SHUTTER ADJUSTMENT section for details).
Flashing (sealant OK)
Clamps
( included)
Termination Cap
Screws
( included)
Vent adapter
( included)
Air restrictor
Required for
installation
(exhaust side) if
length of vent run
is 20' or more
3" Flexible
vent pipe
(Exhaust)
3" Flexible
vent pipe
(Intake)
DO NOT
use
sealant
on pipes
D1-30 shown
(model may vary)