Owner`s manual
10
Table 4 - Minimum Fireplace Dimensions
SPECIFICATIONS AND DIMENSIONS (cont.)
Fig. 10-1 Minimum Fireplace Dimensions
A
B
C
D
* For elevations above 2,000 feet, the BTU rate of the unit is reduced by
4% for each additional 1,000 feet. To install the unit above an elevation of
2,000 feet, you must use proper orifi ces based on the de-rated BTU.
Remote Control
Supply voltage
4.5 V
(three 1.5 V AAA batteries)
Ambient temperature ratings 32 - 122 °F (0-50 °C)
Radio frequency 315 MHz
Receiver
Supply voltage
6.0 V
(four 1.5 V AA batteries)
Ambient temperature ratings 32 - 140 °F (0-60 °C)
Radio frequency 315 MHz
Fan Control Module
Supply voltage/frequency 120 V / 60 Hz
Ambient temperature ratings 32 - 140 °F (0-60 °C)
Output voltage/frequency/current 120 V / 60 Hz / 5 A
Aux switched output 120 V / 60 Hz / 2 A
Fan speed output 120 V / 60 Hz / 1 A
Table 6 - Technical Data Specifi cations
Description
Dimension
D1-25 D1-30 D1-36
A. Front Width 30" 34"
37"
B. Rear Width 20" 20
1
/
2
" 22
1
/
2
"
C. Depth 15" 18
1
/
2
" 19
1
/
2
"
D. Height 19" 22" 25
1
/
2
"
Model
Natural Gas Propane Gas
BTU
Rating
Orifi ce Size
BTU
Rating
Orifi ce Size
Front Rear Front Rear
D1-25
(0-2000 FT)
* 25,000 #42 - 20,000 #55 -
D1-30
(0-2000 FT)
* 32,000 #50 #45 31,000 #57 #55
D1-36
(0-2000 FT)
* 38,000 #48 #43 36,000 #57 #54