Operating instructions
2
TABLE OF CONTENTS
PRODUCT DATA TABLE AND GAS TYPE SPECIFICATIONS
Counter Opening* Dimension
Height*
30.5 cm
Width*
62.9 cm
Depth*
45.1 cm
LPG gas category I
3+
I
3B/P
(30) I
3B/P
(50)
Total heat input (kW) 12.3 12.3 12.3
Injector sizes (mm/gauge**) 1.321/#55 1.321/#55 1.181/#56
NAT gas category I
2H
(20) I
2E
(20) I
2E+
(20/25) I
2L
(25)
Total heat input (kW) 12.3 12.3 12.3 12.3
Injector sizes (mm/gauge**) 1.994/#47 1.994/#47 1.994/#47 1.994/#47
**NOTE: Oriļ¬ ces are marked in U.S. gauge numbers above. Use these tables to translate.
LPG Gas Category Supply
Pressure (mbar)
Destination Countries
I
3+
(28,30/37) BE, CH, CY, CZ, EE, ES, FR, GB, BR, IE, IT, LT, LU, LV, PT, & SK
I
3B/P
(30) AT, CY, CZ, DE, DK, EE, FI, FR, GB, GR, HU, IS, IT, LT, LU, LV, MT,
NL, NO, SE, SI, SK, & TR
I
3B/P
(50) AT, CH, DE, FR, HU, LU, NL, & SK
NAT Gas Category Supply
Pressure (mbar)
Destination Countries
I
2H
(20)
AT, CH, CZ, DK, EE, ES, FI, GB, GR, IE, IT, LT, LV, NO, PT, SE, SI, SK, & TR
I
2E
(20)
DE, LU, & PL
I
2E+
(20/25)
BE & FR
I
2L
(25)
NL
This appliance must be used with the appropriate gas and at the
correct gas pressures. Failure to comply may result in hazardous
situation.
*Note: If using an insulating liner consult liner instructions for
counter cut-out dimensions.
SAFETY WARNINGS & CODES 1
TABLE OF CONTENTS 2
PRODUCT DATA TABLE AND GAS TYPE SPECIFICATIONS 2
PARTS LIST 3
PLANNING FOR INSTALLATION OF YOUR DELUXE SERIES BARBECUE 4
FIRE MAGIC DELUXE GOURMET SERIES BARBECUE ORIFICE CONVERSION 5
AIR SHUTTER ADJUSTMENT 6
SAFETY INFORMATION AND WARNINGS 7
COMMON GAS EU CONNECTORS 8
COMMON GAS EU CONNECTOR DIAGRAMS 9
INSTALLING YOUR FIRE MAGIC DELUXE GOURMET SERIES BARBECUE 10
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS 11
CHECKING AND CONVERTING GAS TYPE 12
LIGHTING (IGNITION) INSTRUCTIONS 13
ACCESSORIES 14
BARBECUE CARE & CLEANING 15
BARBECUE COVER 15
REPLACING THE IGNITOR BATTERY 17
TROUBLESHOOTING 17
FIRE MAGIC OUTDOOR GAS BARBECUES LIMITED WARRANTY 18
REV 1 - 0609201134
L-C2-24206