Owner`s manual
20
BURNER INSTALLATION
BURNER INSTALLATION GUIDELINES
This fi replace is designed to be installed with an R.H.P. vented/unvented gas appliance. The gas appliance
is purchased separately. Follow all owner's manuals included with the appliance and decorative media to complete
installation.
Note: The gas appliance will come equipped with a fl ex connector. Remove that connector, and connect the
existing fi replace fl ex connector to the appliance.
Make sure to tighten every joint securely.
LEAK TEST
Turn on the gas supply and the key valve, and test at all connections for leaks using a soapy water solution.
If bubbles appear, a leak is present. Turn off the gas and tighten at all connections. Repeat until no leaks are
present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USE A
FLAME TO CHECK FOR LEAKS.