Owner`s manual
18
INSTALLATION
IMPORTANT
For all valves, the air MUST be purged from the gas line before the ODS pilot will light properly. The time taken to
do this will depend on the length of gas line from the meter to the unit and the length of time since the unit or gas
line was last used (in the case of non-use during warm weather, for example). It may take from 3-15 minutes before
all the air is purged and the ODS pilot will light properly. This is done using different methods, depending on which
valve is fi tted to the unit. Follow the LIGHTING INSTRUCTIONS in this manual for your specifi c valve type.
G18-16/18-15(M)(P) - Hold in the control knob at PILOT (see Fig. 18-3).
G18-16/18-01V(P) - Hold down control knob at PILOT (see Fig. 18-4).
CONTROL SETTINGS
Before you install your log set, review your corresponding model control valve layouts.