This appliance is for installation in a solid-fuel-burning fi replace (masonry fi replace or manufactured
fi replace) with a working fl ue and constructed of noncombustible material.
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION
CONTAINED IN THIS OWNER’S MANUAL, INCLUDING:
A. PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY GUIDELINES
B. VENTILATION AND CONFINED SPACE INFORMATION
C. INSTALLATION SAFETY GUIDELINES
CHECK GAS TYPE (natural or L.P.). The gas supply must be the same as stated on your gas log set
rating plate. If the gas supply is different, DO NOT INSTALL. Contact your dealer for immediate
assistance.
1. Adjustable open-ended wrench
2. Pliers
3. L.P. gas-resistant pipe compound or
Tefl on tape
4. Soapy water solution & brush for leak detection
5. Standard screwdriver
6. Manometer (recommended for checking gas
pressure)
Tools Required:
Note: To install your Real-Fyre
®
unvented gas log set, your fi replace must have a gas-supply line
that has been installed by a qualifi ed professional service technician in accordance with all
local codes. Refer to the PARTS LIST when installing the unvented gas log set.
IMPORTANT
Be sure you have read and understand all safety precautions and warnings
contained in this manual.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Center the burner assembly in the fi replace. Make certain that no part of the assembly protrudes beyond the
face of the fi replace.
3. Attach the large adapter fi tting of the fl ex connec tor kit to the fi replace gas-supply line using pipe compound
resistant to L.P. gas or Tefl on tape. Tighten the connection. Connect one end of the fl ex connector to the large
adapter, and the other end to the adapter on valve assembly.
Refer to the PARTS LIST when installing the unvented gas log set.
WARNING
Do not connect this appliance directly to a high-pressure natural gas line or an unregulated L.P. tank.
LEAK TESTING
Make sure that the control valve on the burner system is in the OFF position. Carefully turn on the gas to the
fi replace and leak test at all connections with a soapy water solution (equal parts liquid detergent and water). If
bubbles appear, a leak is present. Turn off the gas and tighten all connections, then turn on the gas and repeat
the leak test. Repeat until no leaks are detected.
NEVER USE A FLAME TO CHECK FOR GAS LEAKS.
These gas logs may be installed as vented decorative log sets in compliance with ANSI Z21.60b-2004 and
National Fuel Gas Code, Section 6.6. The minimum permanent free opening of the fi replace chimney or chimney
damper must be met per the Chimney Vent Opening Table on pg 3 of this manual. Chimney damper must be
fi xed in a manner to maintain permanent free opening at all times. To accomplish this, install a screw or bolt
in the edge of the damper to prevent closing, or drill holes in the damper or remove the damper.
CONNECTING THE GAS TO THE BURNER SYSTEM
WHEN USED AS A VENTED DECORATIVE APPLIANCE (PER ANSI Z21.60b-2004)