Manual On/Off Systems
AV-17 (knob) or AV-18 (rod handle) ................ Manual On/Off, match lit, no pilot
Manual Safety Pilot Systems*
SPK-20 (knob) or SPK-21 (rod handle) .......... Standard pilot
SPK-26 ........................................................... Low-profi le valve
Remote Safety Pilot Systems*
APK-11, EPK-1 ............................................ Toggle switch
APK-11, EPK-1 and WS-1 ........................ Wall switch
APK-11, EPK-1 and WS-2 ......................... Wall timer
APK-11, EPK-1 and WCS-1 ..................... Wood chip switch
APK-11, EPK-1 and RRF-1 ....................... 110V remote
APK-11, EPK-1 and RUS-1 ....................... RUS remote
APK-11, EPK-1 and PC-100 ..................... Pine cone remote
APK-15, APK-17............................................... Variable fl ame-height remote
PC-106 .......................... Pine cone remote
* When systems are to be used with propane gas, add a “P” to the control model No. (e.g., APK11P). Propane burner sets require a
safety pilot system. Not all safety pilot systems are available for all burner sizes.
INSTALLATION (Cont.)
Fig. 8-1
Fig. 8-2a Fig. 8-2b
Open
Closed
DAMPER
WHEN THE BURNER SET IS OPERATING, THE DAMPER MUST BE FULLY OPEN.
A damper clamp (Fig. 8-1) is provided as a means to prevent full closure of the fi replace damper blade. This
clamp is easily attached to most damper blades with pliers or wrench, and must be permanently installed. The
clamp is designed to prevent accidental closure of the damper when installed as illustrated (Fig. 8-2a and
b). Should the damper clamp not fi t, have a permanent stop installed.
MAINTENANCE
Periodically check burner for excessive dirt and soot. Clean with a soft brush. Be sure burner pan is fi lled
with glass (see section on GLASS PLACEMENT).
Periodically examine and clean the venting system of the solid-fuel-burning fi replace. This should be
conducted by a qualifi ed professional or the gas supplier.
PETERSON CONTROL SYSTEM OPTIONS
When using a pilot/thermocouple, pilot/generator safety valve system, keep the pilot/assembly clear of sand,
glass, granules, etc. or pilot outage will occur, read and follow lighting instructions (included in safety pilot
kit).