Owner`s manual
2
No. L-A2-22609
REV 3 - 0903201116
The installation, including provisions for combustion and ventilation air, must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code, ANSI Z223. 1 (NFPA54).
The appliance and its individual shutoff valve must be disconnected from the gas-supply piping system when
testing the system at test pressures in excess of ½ psig.
The appliance must be isolated from the gas-supply piping system by closing its individual manual shutoff valve
during any pressure testing of gas-supply system at test pressures equal to or less than ½ psig.
The minimum inlet gas-supply pressure for the purpose of input adjustment is 5" for natural gas and 10" for
propane gas. The maximum inlet gas-supply pressure for this burner is 10.5" for natural gas and 13" for propane
gas. A fi replace screen must be in place when the pan burner set is burning.
WHEN GLASS FIREPLACE ENCLOSURES (DOORS) ARE USED, OPERATE THE GAS BURNER SET WITH
THE GLASS DOORS FULLY OPEN. KEEP APPLIANCE AREA CLEAR & FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
The minimum size fi replace in which the burner is to be
installed is listed in Table 2-2.
IMPORTANT SAFETY INFORMATION
CHECK TO BE SURE VENTED GAS BURNER IS FOR PROPER GAS TYPE
Peterson PB Series burner sets are designed for use with natural gas, unless clearly labeled for propane. Never
use propane gas in a burner set designed for natural gas, or natural gas in a burner set designed for use with
propane gas.
Burner
Size
Unregulated
Natural Propane
18" 75,000 BTU 60,000 BTU
24" 90,000 BTU 75,000 BTU
30" 90,000 BTU 80,000 BTU
Table 2-1
The minimum-size fi replace in which the burner is to
be installed is listed in the table below:
Burner Depth Height
Front
Opening
Width*
18" 16" 16"
22"
24" 16" 16"
28"
30" 16" 16"
34"
*Add 4" to the minimum front opening width if the burner is to be
installed with a pilot kit. Double this measurement to center burner.
Table 2-2
TABLE OF CONTENTS
IMPORTANT SAFETY INFORMATION 2
PARTS LIST 3
IMPORTANT SAFETY INFORMATION (Cont.) 4
PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY GUIDELINES 4
GLASS QUANTITY DETERMINATION 5
LOG SET NOTES PAGE 6
INSTALLATION 7
BURNER PLACEMENT & ASSEMBLY 7
CONNECT GAS SUPPLY 7
GLASS PLACEMENT 7
DAMPER STOP 8
MAINTENANCE 8
PETERSON CONTROL SYSTEM OPTIONS 8
MANUAL LIGHTING INSTRUCTIONS 9
WARRANTY 10
Minimum Free Opening Area of Chimney Damper for Venting
For Factory-Built Fireplaces
Burner Sizes
For Masonry-Built Fireplaces
Burner Sizes
Chimney Height
18" 24" 30" 18" 24" 30"
15' 46 sq. in. 56 sq. in. 69 sq. in. 50 sq. in. 60 sq. in. 73 sq. in.
20' 42 sq. in. 50 sq. in. 61 sq. in. 46 sq. in. 54 sq. in. 65 sq. in.
30' 37 sq. in. 45 sq. in. 55 sq. in. 41 sq. in. 49 sq. in. 59 sq. in.
Note: The minimum chimney height from hearth to top of chimney is 15'.
Table 2-3